background image

Straight Action Hand Tool

Instruction Sheet

(416--39 Rev A)

STS--M--182--2430--11--A

LOC B

1

of 4

E

2010 Copyright Protected, SAMTEC

All Rights Reserved.
All product names, logos, or company names might be trademarks of their respective owners.

CUSTOMER SERVICE 1--800--SAMTEC9

26 MAY 10

CAT- HT- 182- 2430- 11

PROPER USE GUIDELINES

Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools. Hand tools are intended for occasional use and low volume

applications. A wide selection of powered application equipment for extended--use, production operations may be available.

Figure 1

Front of

Tool

Insulation

Crimper

Insulation

Anvil

Wire Barrel

Anvil

Wire

Crimper

Insulation

Adjustment

Knob

1. INTRODUCTION

CAT--HT--182--2430--11 was designed to crimp

T--1M82 terminals.

The wire crimper bottoms against the anvil before

the ratchet releases. This is a design feature that

assures maximum electrical and tensile

performance of the crimp. Do NOT re--adjust the

ratchet.

Dimensions in these instructions are in metric

units [with inches in brackets]. Figures and

illustrations are for reference only and are not

drawn to scale.

2. DESCRIPTION

The front of the tool, is marked with the tool part

number, wire size ranges, and crimp height

specifications.
The tool features a fixed die (crimper), a movable die

(anvil), a locator/insulation stop, and a ratchet. Many

tools feature an insulation adjustment knob which is

used to regulate the crimp height of the contact

insulation barrel during the crimping operation. The

locator/insulation stop positions the contact, and limits

the insertion distance of the stripped wire into the

contact. In use, the locator/insulation stop rests in the

locator slot of the contact (See Figures 1 and 2). The

ratchet assures full crimping of the contact. Once

engaged, the ratchet will not release until the dies

have been fully closed.

3. CRIMPING PROCEDURE

Do NOT cut or nick the wire strands during wire

stripping.

Refer to Figure 2 for wire preparation information

before applying the terminal.

1. Hold the tool so that the front side is facing you.

2. Ensure that the tool ratchet is released by

squeezing the tool handles and allowing them to

open

fully

.

3. Holding the contact by its mating portion and

looking straight into the crimp section, insert the

contact from the

back

of the tool into the

appropriate crimp chamber.

4. Position the contact between the crimpers so

that the locator/insulation stop enters the slot in the

contact. The wire barrel should butt against the

locator/insulation stop. Refer to Figure 1.

5. Holding the contact in this position, squeeze the

tool handles together until the insulation anvil starts

entry into the insulation crimper (usually two

ratchet clicks). Do not deform the insulation barrel

or wire barrel.

6.

Insert a properly stripped wire through the

locator slot and into the wire barrel of the contact

until the insulation butts against the

locator/insulation stop.

7. Holding wire in place, crimp contact to the wire

by squeezing the tool handles together until the

ratchet releases.

8. Allow tool handles to open

fully

and remove the

crimped contact from the tool.

CAUTION

!

NOTE

i

CAUTION

!

US050136 - 2012-11-28T20:17:17Z

Downloaded from

Arrow.com.