60
9.4 Screen Config
To configure a LED display with system configuration files, click
Screen Config
button
fromthe tool bar or select
Tools
->
Screen Config
from the main menu of the NovaLCT
application main interface to open the Screen Config window. Shown in Fig.9-5 is the
Screen Config window.
Fig 9-5
Step 1:
Set the
Current Operation Communication Port
This is the port that connects the sending board (controller) to be configured to the control
computer. If only one serial port of the computer is used to connect the LED display
control system, the used serial port will be automatically set as the current serial port.
Otherwise, if multiple serial ports are used to connect control systems to the computer
(one serial port for one control system), the serial port that is used to connect the control
system which is to be configured should be set as the current serial port. If it's the mode
with no sending board, please set the corresponding network port.
Step 2:
Load system configuration file
Select
Load Config File
option, use
Browse
button to select the system configuration file
to be loaded and then click
Next
. The selected configuration file will be automatically
loaded to the LED display system. The LED display system will have been configured
when the load operation is finished.