18 _ Removal and Reassembly
Part
Figure
Description
Disassembling the
Tub
1. Remove the 2 screws fixing GUIDE-WIRE, 6
screws fixing FRAME-PLATE(U).
2. Remove the 6 bolts fixing WEIGHT BALANCER
and then pull it towards with caution.
3. Remove the 4 bolts fixing DAMPER to take ASSY
TUB out.
4. Remove all wire and hose connected the ASSY-
TUB.
5. Open the cap of SPRING-HANGER to take ASSY-
TUB out.
6. Lift the ASSY-TUB with two people carefully with
holding SPRING-HANGER.