Samsung WF241ANW Troubleshooting Manual Download Page 4

Door Lock Check

 

Test 1

 

Test 2

 

Connector CN2, pin 1 (BLUE) and CN2 Pin 3 
(BLACK)

 

When Door is Locked 120VAC 
Unlocked 0VAC 

 

With Power Off, the resistance be-
tween these pins will be 0Ω when 
locked

 

Drain Motor Check

 

Test 1

 

Test 2

 

Connector RY1, pin 2 (Blu) and CN5 Pin 4 (grey)

 

120VAC with the pump On and 0VAC 
with the pump off

 

Power Off, the resistance should be 
13.9Ω

 

Water Valve Check

 

Test 1

 

Test 2

 

Connector CN2 Pin 3 (black) to CN5 Pin 2 (Red),  
Pin 1 (Blue) or Pin 3 (Pink)

 

120VAC with the Valve On and 0VAC 
with the Valve off

 

Power Off, valve resistance is from 
1202Ω - 1245Ω

 

Heater Relay Check

 

Test 1

 

Test 2

 

Connector CN2 Pin 3 (Blk) and RY3 (heater relay) 
Pin 2 (Red)

 

120VAC with the Heater On and 0VAC 
with the Heater off

 

Power Off, heater resistance is  
16.6 Ω

 

Error Type  

Error Mode  

Details  

LED  LCD 

                                                         
Water Level Sensor 

               
LE       

 

Check the Hose where the sensor is connected, may be loose, 
pinched, damaged or clogged. Also check the sensor it may be 
disconnected or defective. The Main PCB may also be defective  

                                                 
Motor Drive  Error or 
Hall Sensor error  

 

        
3E 

 

Check the  motor drive connector, it may be loose. The hall sensor 
may be disconnected, loose or damaged . Check for a foreign ob-
ject inside the motor or motor damage. The stator might be loose 
or damaged. The drum might be overloaded from too many 
clothes or the relay or PCB  might be defective.      

 

E3 

bE 
25 

                                              
Water Supply 

Error 

                        
nF   

 

Check the water valve wiring harness. 

Check whether the water supply valve is clogged with foreign ma-
terial and whether water is supplied properly. 

Check for reversed fill hoses 

Check water temperature, if sensed as higher than 50 ˚C in the 
Wool or Lingerie cycle it will create error. 

Check the relays, if they operate correctly replace the Main PCB. 

Fill Hoses Reversed  nF1 

 

Correct Hot/Cold hose connections 

System Error 

SF1 
SF2  
SF3 

 

Replace PCB

 

EEPROM Clear Mode: 

-All option settings are reset to default values. 

!! When Main PCB is replaced, EEPROM should be reset !! 

How to Enter: 
-The unit needs to be on. 
-Press Delay Start and Power Keys at the same time.  