background image

 
 

#  tsWF206   RevD 03/21/2011

                                                                                                                                                                  3 

 

CN9

 

1 Motor Pwr U Phase (Blu)

 

2 Motor Pwr V Phase (Wht)

 

3 Motor Pwr  W Phase (Red)

 

CN10

 

1 Main Valve (Blu)

 

2 Hot Valve (Red) 
4 Bleach Valve (Pnk)

 

6 Drain Pump (Blk)

 

7 Door Lock Close (Sky)

 

8 Door Lock Open (Wht)

 

CN8 (Hull Sensor)

 

1  +5 vdc (Pnk)

 

2 Sensor Signal (Red)

 

3 Sensor Signal (Blu)

 

4 Ground (Org)

 

CN7 
2 Door Lock & Valve common (to L)(Blk)

 

CN5

 

1 AC Pwr (N) (Wht)

 

3 AC Pwr (L) (Blu)

 

CN3

 

3 Water Temp Thermistor(Wht)

 

4 Door Sw (Brn)

 

6 Water Temp Thermistor Gnd. (Org)

 

7 Water Level Sensor (Vio)

 

8 Water Level Sensor (Pnk)

 

CN1 & CN2

 

PCB Sub (Display)

 

Water Temperature Thermistor Check

 

Test 1

 

Test 2

 

Connector CN 3 Pin 3 (White) and CN3 Pin 6 
(Orange)

 

Operating voltage at Room temperature 
-

 

Operating Resistance at Room 
Temperature (Power off) discon-
nect CN3

 

2.5VDC (5VDC May indicate a connector 
issue)

 

12kΩ-14kΩ

 

Door Switch Check

 

Test 1

 

Test 2

 

Connector CN3 pins #6(Org) & # 4(Brn)

 

5VDC Door Open, 0VDC Door Closed

 

Operating Resistance with 
power off

 

 

open with door open, short with 
door closed.

 

Water Level Sensor Check

 

Test 1

 

Test 2

 

Voltage: Connector CN 3 pins #6(Org) & # 7(Vio)  
And Connector CN 3 Pins #6(Org) & #8(Pnk)

       

Resistance: Connector CN 3 Pin 8 (Pink) and CN7 
Pin 7 (Violet)

 

Operating voltage at no water in the 
drum-

 

Operating Resistance  (Power 
off)

 

2.5VDC

 

CN3 Pin 8 (Pink) and Pin 7 
(Violet) 22- 24Ω

  

Hall Sensor Check

 

Test 1

 

Test 2

 

Connector CN8 pins #4(Org) & # 2(Red) additionally  
4(Org) & # 3(Blu)

  

Manually spin the drum to see the volt-
age change, Power On

 

N/A

 

0Vdc or 3.75Vdc

 

Motor Check

 

Test 1

 

Test 2

 

Connector CN9 Pin 1  (Blue), Pin 2 (White) and Pin 
3 (Red)

 

Power Off 11.5Ω across Pins 1-2, Pins 1
-3, & Pins 2-3

 

N/A

 

A/C Power Check

 

Test 1

 

Test 2

 

Connector CN 5 Pins 1 (White) and 3 (Blue)

 

Power On 120VAC

 

N/A

 

CN11 (MEMS PCB)

 

1 (Blu)

 

2 (Wht)

 

3 (Yel)

 

4 (Org)

 

5 (Pnk)

 

Summary of Contents for WF206BNW/XAA

Page 1: ...at the Whites is turned on Next press the Start Pause Key The door status will be displayed OP if open CL if closed 3 Extra Wash Then turn the Dial so that the Perm Press is turned on Next press the Start Pause Key The door lock Switch status will be displayed UL if unlocked Lo if locked 4 Extra Wash Then turn the Dial so that the Delicate Hand Wash is turned on Next press the Start Pause Key 0 wi...

Page 2: ... tsWF206 RevD 03 21 2011 2 Model NOTE ...

Page 3: ...C May indicate a connector issue 12kΩ 14kΩ Door Switch Check Test 1 Test 2 Connector CN3 pins 6 Org 4 Brn 5VDC Door Open 0VDC Door Closed Operating Resistance with power off open with door open short with door closed Water Level Sensor Check Test 1 Test 2 Voltage Connector CN 3 pins 6 Org 7 Vio And Connector CN 3 Pins 6 Org 8 Pnk Resistance Connector CN 3 Pin 8 Pink and CN7 Pin 7 Violet Operating ...

Page 4: ...eater re lay Pin 1 Red 120VAC with the Heater On and 0VAC with the Heater off Power Off heater resistance is 16 6 Ω Error Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Ch...

Page 5: ...use of moisture If the main PCB s communication circuit is faulty replace it EEPROM Fault 11 Go to EEPROM Clear Mode If display shows FAiL Replace Ma chine Control Board Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switchin...

Page 6: ...ly Verify the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause repositi...

Page 7: ...etergent for the water hard ness and soil level of the clothing over sudsing will occur When this happens there will be leaks out of the detergent drawer and door Please advise con sumer of proper de tergent usage Varies by model Location considerations Do not install your washer in areas where water may freeze since your washer will always maintain some water in its water valve pump and hose area...

Reviews: