8) Power-out compensation function
●
If power is out on selected process, the process before power out is stored to EEPROM, once power is
back the process before power out continues.
●
When power is back, washing process starts from the process at the point of the power out, rinse/drain
process starts from the initial process.
9) Water heater Error function
①
This function starts working, when the heater works abnormally.
(this function begins sensing the heater 2 minutes later, after the heater operating)
②
The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 2 minutes
(Y=A2-A1)
- For 10 minute late, the variance of temperature(Y) is less than 2
℃
, "HE2"message is displayed on the
panel.
③
The value of the initial thermistor(A1) is compared with that of the thermistor(A2) in 11 minutes
(Y=A2-A1)
- For 1 minute the variance of temperature(Y) increases more than 40
℃
, "HE1"message is displayed on
the panel.
④
At this time heater, Error "HE2 (heater do not work), HE(overheated)" is displayed and all working
process off
⑤
The heater operating continues during heating hours, if washing hour is left over, the residual washing
process keeps going without heating.
POWER-OUT COMPENSATION FUNCTION PROCESS
WASHING
START
RINSE/DRAIN
PROCESS
RINSE/DRAIN
START
FINISH
POWER OUT
POWER BACK
SAVE DATA
to EEPROM
SAVE DATA
to EEPROM
READ DATA
(TIME)
MICOM RESTORE
MICOM RESTORE
RESTART
PROCESS
POWER OUT
POWER BACK
Summary of Contents for WF-F1256
Page 16: ...6 2 2 OVERVIEW OF THE WASHING MACHINE...
Page 19: ...9 3 PRODUCT SPECIFICATIONS 3 1 OVERVIEW OF THE CONTROL PANEL...
Page 42: ...50 9 SCHEMATIC DIAGRAM 9 1 EMZ F1256 F1056...
Page 43: ...51 9 2 ROLD F856...
Page 53: ...51 9 SCHEMATIC DIAGRAM 9 1 EMZ F125AC F105AV...
Page 54: ...52 9 2 ROLD F85A...
Page 55: ...51 9 SCHEMATIC DIAGRAM 9 1 EMZ F125AC F105AV...
Page 56: ...52 9 2 ROLD F85A...