![Samsung WA-7000HA PJT Service Manual Download Page 27](http://html.mh-extra.com/html/samsung/wa-7000ha-pjt/wa-7000ha-pjt_service-manual_358678027.webp)
Troubleshooting _ 25
Symptom
Check Code
Countermeasure
Troubleshooting Procedure
Measurement Picture
Door
Check
►
DC
This may occur when the
door switch is defective.
This may occur when the
main PCB is defective.
•
Check
if
a
dE
Check
occurs
durin
g
the
boiling course.
•
As
this
Check
occurs
because
the
door
is
opened,
close
the
door
.
•
Since
120V
pow
er
is
connected,
check
if
the
power
cord
is
disconnected
or
check
the
insulation status and repair it if necessary
.
•
If
the
m
ain
PBA
door
detection
cir
cuit
is
defective,
replace
it.
1.
Check
the
resistance
for
Reed
SW
(Checking
Part
:White-Green
Wire)
-
Resistance:
Approx
0.2Ω
between the terminals of
Reed SW
.
2.
Check
the
resistance
for
Motor
(Checking
Part
:
Black-Brown
Wire)
-
Resistance:
33Ω
to
46Ω
between
the terminals of Motor
.
►
DC1
DC2
The
door
lock
switch
unit
is
not inserted.
The
door
lock
switch
unit
is
damaged.
The wire is disconnected.
The
door
lock
switch
unit
is
defective.
This may occur due to a
defect of the main PCB.
•
Check
whether
the
door
lock
switch
unit
is
inserted.
•
Check
whether
the
door
lock
switch
unit
is
damaged.
•
Check
the
disconnection
of
the
wire.
•
If
the
door
lock
switch
unit
is
defe
ctive,
replace it.
•
If
the
m
ain
PCB
is
defective,
repla
ce
it.
3.
Check
the
resistance
for
Lock/
Unlock
Contact
(Checking
Part
:
Lock
White-Red
Wire
Unlock
White-Blue
Wire)
- Resistance: Resistance:
Approx
0.2Ω
between
the
terminals of Contact.
Check
the
Door
Lock/Unlock
state.
Switch
Check
(Main
Relay
Check)
►
BC2
The Power button is
continually pressed.
A
button
other
than
the
Power button is continually
pressed.
• Check
whether
either
the
Power
switch
or
a
tact switch is continually pressed.
• Check
whether
the
service
PBA
holding
screws are fastened too tight. If they are
fastened
too
tight,
loosen
them
a
little.
• If
the
main
PBA
switching
IC
on/of
f Check
has
occurred,
replace
the
main
PBA.
• The
“E2”
Check
occurs
if
the
main
relay
connections
are
incorrect.
Check
the
connections.
If
there
is
no
Check
in
the
connections,
replace
the
main
PBA.
Check
the
contact
between
the
control panel buttons and their
corresponding tact switch.
-
There must be a gap between a
control panel button and its
corresponding micro switch.
Otherwise,
an
Check
occurs
after
approx.
30
seconds
has
passed.