![Samsung UQ18A6RC Service Manual Download Page 9](http://html.mh-extra.com/html/samsung/uq18a6rc/uq18a6rc_service-manual_1187757009.webp)
8
3-2 Fault Diagnosis by Symptom
3-2-1 No Power(completely dead)-Initial diagnosis
1) Checklist :
(1) Is input voltage normal? (rating voltage ±10% range)
(2) Is AC power linked correctly?
(3) Are connections between primary side, secondary side of the power transformer and PCB good.
(4) Is input voltage of DC regulator IC KA7805 (IC02) normal? (11VDC-12.5VDC)
(5) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC-5.5VDC)
2)
Troubleshooting procedure
Replace PCB
display
Is DC voltage of PCB
display normal?
Remove power cord and plug in again
in approx. 5 seconds
Is operation lamp blinking?
Does operation start when
run/stop button on the remote
controller unit pushed?
Is transmission display of the remote
controller unit blinking?
Is "beep"sound heard from the main
unit?
Is DC voltage of the PCB module
normal?
Are voltages of #8 (compressor),
#7 (4 way valve) and #6 (outdoor fan) of
the micom normal? (5VDC)
Is voltage of #60 (indoor fan) of the
micom normal?
Is voltage at #33 terminal of the Micom normal?
; 0VDC
Is voltage at #18 terminal of the Micom normal?
; 5VDC
Is the input rating
±
10%
range applied to the
between #1 and #3 of CN78
¥Check linkage between
power cord and
terminal tap
¥Check fuse
Is 11~12.5VAC appear in
the input side of the DC
regulator IC KA7805(ICO2)?
Refer to replace
PCB Module
YES
NO
YES
NO
YES
YES
YES
NO
YES
YES
YES
DC5V
10ms
10ms
100ms
NO
NO
OK
YES
YES
YES
YES
NO
NO
YES
Normal
Refer to remote control
unit fault diagnosis
Refer to Replace
PCB module.
Is output voltage of ICO2 normal?(DC5V)
Check connections
compressor 4-way
valve, outdoor fan and
indoor fan.
Are voltages at RY71(Compressor)
RY73 (4 way valve) and RY 72 (Outdoor fan)
normal? (DC12V)
Is voltage at SS71(indoor fan)
Replace
RY71, RY73,
RY72 and
SS71
NO
NO
NO
Is voltage output terminal of
D101~D105(IN4007) normal?
Replace ICO2
Check PCB pattern. Module
Refer to Replace module PCB.
Replace IN4007
Replace
micom
Is voltage at #52 terminal of the micom
normal?
Are voltage at #48 and #49 of the
micom normal?
NO
NO
NO
YES
NO
NO
NO
YES
OK
Is operation normal?
Replace resonator (X501)
9-00188A(3)-TS 4/17/01 5:16 PM Page 8
Summary of Contents for UQ18A6RC
Page 23: ...22 6 PCB Diagrams 6 1 Main PCB PD TQ24A1R 00 ...
Page 25: ...24 7 Wiring Diagrams 7 1 Indoor Unit AQ24A2RC AQ18A6RC ...
Page 27: ...26 ...
Page 28: ...ELECTRONICS ...