UN46ES8000FXZA
Fast Track Troubleshooting Manual Rev –
8/20/12
Power-Up Sequence (CN201):
1. Standby Voltage:
Pin 4 (5Vdc)
2. Power-ON:
Pin 2 (Low-Hi voltage transition)
3. Low Voltages:
Pin 1, 3, 7, 9, 11, 12, 13
4. Backlight On:
Pin 10 (5Vdc)
Forced Backlight-On Mode:
1. Disconnect Power Cord
2. Disconnect wire harness from CN201
3. Re-Connect Power Cord
4. LED Backlight should immediately turn on
NOTE: If LED backlight fails to come on, place a jumper
wire between Pin 2 and Pin 4 and try again
CN201