E-
15
ENGLISH
Connecting the connection cord
The indoor unit is powered by the outdoor unit by means of a H07 RN-F
connection cable (or a more power model), with insulation in synthetic rubber
and jacket in polychloroprene(neoprene), in accordance with the requirements
of standard EN 60335-2-40.
1
Remove the screw on the electrical component box and remove the cover plate.
2
Route the connection cord through the side of the indoor unit and connect
the cable to terminals; refer to the figure below.
3
Route the other end of the cable to the outdoor unit through the ceiling &
the hole on the wall.
4
Reassemble the electrical component box cover, carefully tightening the screw.
5
Be sure to run the power supply cable and the communication cable through
electronic conduit as seen in below picture.
Always remember to connect the refrigerant pipes before performing the electric connections.
When disconnecting the system, always disconnect the electric cables before disconnecting the refrigerant pipes.
Always remember to connect the air conditioner to the grounding system before performing
the electric connections.
CAUTION
conduit
communication cable
Power supply cable
Outdoor Unit
USA_DB98-29515A_IM_E_3.3.08.indd 15
2008-3-13 11:05:09
Air Marketing Group LLC