Samsung Electronics
14-10
Reference Sheet
Low pressure side
(Gas side)
High pressure side
(Liquid side)
Relocation of the air conditioner
• Refer to this procedure when the unit is relocated.
• Carry out the pump down procedure(refer to the details of 'pump down').
• Remove the power cord.
• Disconnect the assembly cable from the indoor and outdoor units.
• Remove the flare nut connecting the indoor unit and the pipe.
• At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
•
Disconnect the pipe connected to the outdoor unit.
At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material
entering.
• Make sure you do not bend the connection pipes in the middle and store together with the cables.
• Move the indoor and outdoor units to a new location.
• Remove the mounting plate for the indoor unit and move it to a new location.
14-7-2 “Pump down” Procedure
Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.
3) Set the unit to cool operation mode.
(Check if the compressor is operating.)
4) Turn the High pressure side valve clockwise to close.
7) Close the cap of each valve.
5) When the pressure gauge indicates "0" turn the
Low pressure side valve clockwise to close.
6) Stop operation of the air conditioner.
1) Remove the caps from the Low pressure side.
2) Turn the Low pressure side valve clockwise to close
and connect a pressure gauge(low pressure side)
to the service valve, and open the valve again.
Summary of Contents for UH052EAS
Page 29: ...Samsung Electronics 5 1 5 Exploded Views and Parts List 5 1 Indoor Unit DH070 052 EAS ...
Page 31: ...Samsung Electronics 5 3 Exploded Views and Parts List 27 26 UH070 052 EAS 5 2 Outdoor Unit ...
Page 33: ...Samsung Electronics 5 5 5 3 Ass y Control Out ...
Page 57: ...9 1 1 Indoor Unit 9 Circuit Descriptions 9 1 PCB Circuit Descriptions Samsung Electronics ...
Page 58: ...9 1 ...
Page 59: ...9 1 2 Outdoor Unit 9 1 PCB Circuit Descriptions 9 2 ...
Page 60: ...Temperature sensor EEV PCB display Communcation Tap motor 4 way valve Samsung Electronics ...
Page 61: ...MEMO Samsung Electronics ...
Page 62: ...Samsung Electronics 9 2 Refrigerating Cycle Diagram 9 3 ...
Page 63: ...Samsung Electronics The red number connecter is not used 10 PCB Diagram 10 1 Indoor PCB 10 1 ...
Page 95: ...Samsung Electronics 13 Block Diagram 13 1 Indoor Unit 13 1 ...
Page 98: ...Samsung Electronics 14 2 Pressure Graph UH052EAS 14 2 UH070EAS ...