![Samsung TDM PLUS Service Manual Download Page 77](http://html1.mh-extra.com/html/samsung/tdm-plus/tdm-plus_service-manual_4019237077.webp)
Troubleshooting
Samsung Electronics
77
No.
LED Display
Displayed
PCB Assy
Meaning
Remarks
Error Code
Red
Green
Yellow
24
z
|
z
MAIN/INVERTER
Comp. wire missing error
Check Comp. wire
E467
25
z
MAIN/INVERTER
Current sensor error
Check Outdoor Inverter
PBA
E468
26
z
|
MAIN
DC-Ling voltage
Sensor error
Check Input
voltage
E469
27
z
|
MAIN
EEPROM read/write error
Check EEPROM
E470
28
z
|
MAIN
Outdoor EEPROM error
Check Outdoor EEPROM
date
E471
29
|
MAIN/INVERTER
IPM(IGBT Module) or PFCM Temperature sen-
sor Error
Check Outdoor Inverter
PBA
E474
30
z
z
MAIN/INVERTER
PFC Overload Error
Check Outdoor Inverter
PBA
E484
31
z
|
MAIN
Input current
sensor error
E485
32
|
MAIN/INVERTER
IPM is over heated.
Check Outdoor Inverter
PBA
E500
33
z
|
MAIN
GAS Leak error
Check indoor and outdoor
unit model
E554
34
z
|
MAIN
Water inlet
temperature sensor error
Check Water
inlet sensor
E901
35
z
|
MAIN
Water outlet
temperature sensor error
Check Water
outlet sensor
E903
36
z
|
MAIN
Refriqerant gas inlet
temperature sensor error
Check Gas
inlet sensor
E906
37
z
|
MAIN
Mixing Valve Outlet
temperature sensor error
Check Mixing Valve
Outlet sensor
E916
|
Off
Blink
z
On
4-5-2 Troubleshooting for outdoor unit(con.)
If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB.