6-3
6. Wiring Diagram
6-3. Connector Functions
Connector
Functions
CN101
CN600
Supplies 5V from the power board to the main board and transmits the PWM output from the
power board to the inverter.
*When a problem occurs: The No Power and Blank Screen errors may occur.
CN1 ~ CN4 In
Transmits the lamp current (6mA ~ 7mA) generated in the inverter to the lamp of the panel.
* When a problem occurs: The Blank Screen error may occur.
CN101
Connects the function board.
* When a problem occurs: The No LED screen and Function failure errors may occur.
CN400
Transmits the LVDS signals from the main board to the panel.
* When a problem occurs: The Blank screen and No Power errors may occur.
6-4. Cables
Use
LVDS 30P FFC cable
Code
BN96-02854N
Photo
Summary of Contents for SyncMaster T190G
Page 9: ...3 6 3 Disassembly and Assembly Memo ...
Page 24: ...1 4 1 Precautions Memo ...
Page 28: ...2 4 2 Product specifications Memo ...
Page 31: ...4 3 4 Troubleshooting 4 2 1 Circuit diagrams when the power does not turn on ...
Page 33: ...4 5 4 Troubleshooting 4 3 1 When a blank screen is displayed Analog ...
Page 34: ...4 6 4 Troubleshooting 4 3 2 Waveforms when no screen is displayed Analog ...
Page 36: ...4 8 4 Troubleshooting 4 4 1 Circuit diagrams when a blank screen is displayed Digital ...
Page 37: ...4 9 4 Troubleshooting 4 4 2 Waveforms when a blank screen is displayed Digital ...
Page 50: ...6 4 6 Wiring Diagram Memo ...
Page 53: ...7 3 7 Schematic Diagram 7 4 Schematic Diagrams IP Board SMPS Part ...
Page 54: ...7 4 7 Schematic Diagram Inverter Part ...
Page 56: ...7 6 7 Schematic Diagrams Memo ...