![Samsung SyncMaster 730MP Service Manual Download Page 3](http://html.mh-extra.com/html/samsung/syncmaster-730mp/syncmaster-730mp_service-manual_1195780003.webp)
1-1-1 Warnings
1.
For continued safety, do not attempt to modify the circuit
board.
2.
Disconnect the AC power and DC Power Jack before
servicing.
1-1-2 Servicing the LCD Monitor
1. PBA and panel components are very sensitive to static
electricity. Always wear anti-static gloves when handling
PBA or panel. Use an anti-static wrist strap and/or work
bench. Keep parts in protective bags until ready for use.
2.
Do not use or apply excessive force when handling
panel. Damage to liquid crystal display may result from
improper handling.
1-1-3 Fire and Shock Hazard
Before returning the LCD monitor to the user, perform the
following safety checks:
1.
Inspect each lead dress to make certain that the leads are
not pinched or that hardware is not lodged between the
chassis and other metal parts in the LCD monitor.
2.
Inspect all protective devices such as nonmetallic control
knobs, insulating materials, cabinet backs, adjustment
and compartment covers or shields, isolation resistor-
capacitor networks, mechanical insulators, etc.
3.
Leakage Current Hot Check (Figure 1-1):
WARNING: Do not use an isolation
transformer during
this test.
Use a leakage current tester or a metering system that
complies with American National Standards Institute
(ANSI C101.1, Leakage Current for Appliances), and
Underwriters Laboratories (UL Publication UL1410,
59.7).
Figure 1-1. Leakage Current Test Circuit
4.
With the unit completely reassembled, plug the AC line
cord directly into a 220V AC outlet. With the unit’s AC
switch first in the ON position and then OFF, measure
the current between a known earth ground (metal water
pipe, conduit, etc.) and all exposed metal parts,
including: metal cabinets, screwheads and control shafts.
The current measured should not exceed 0.5 milliamp.
Reverse the power-plug prongs in the AC outlet and
repeat the test.
1-1-4 Product Safety Notices
Some electrical and mechanical parts have special safety-
related characteristics which are often not evident from visual
inspection. The protection they give may not be obtained by
replacing them with components rated for higher voltage,
wattage, etc. Parts that have special safety characteristics are
identified by on schematics and parts lists. A substitute
replacement that does not have the same safety characteristics
as the recommended replacement part might create shock, fire
and/or other hazards. Product safety is under review
continuously and new instructions are issued whenever
appropriate.
1 Precautions
730MP
1-1
1 Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as electrical shock.
1-1 Safety Precautions
DEVICE
UNDER
TEST
TEST ALL
EXPOSED METAL
SURFACES
(READING SHOULD
NOT BE ABOVE 0.5mA)
LEAKAGE
CURRENT
TESTER
2-WIRE CORD
ALSO TEST WITH
PLUG REVERSED
(USING AC ADAPTER
PLUG AS REQUIRED)
EARTH
GROUND
!
Summary of Contents for SyncMaster 730MP
Page 12: ...Memo 2 Product Specifications 2 8 730MP ...
Page 28: ...Memo 5 Troubleshooting 5 10 730MP ...
Page 30: ...6 Exploded View Parts List 6 2 730MP Memo ...
Page 52: ...Memo 8 Block Diagrams 8 2 730MP ...
Page 53: ...730MP 9 1 9 Schematic Diagrams 9 Wiring Diagram ...
Page 54: ...Memo 9 Schematic Diagrams 9 2 730MP ...
Page 58: ...11 Schematic Diagrams 11 2 730MP 3 4 5 ...
Page 61: ...730MP 11 5 11 Schematic Diagrams 6 ...
Page 64: ...11 Schematic Diagrams 11 8 730MP 7 8 9 10 ...
Page 67: ...730MP 11 11 11 Schematic Diagrams 11 12 ...