Samsung SSA-S1000 User Manual Download Page 2

2_

 

Safety information

safety information

CAUTION

RISK OF ELECTRIC SHOCK.

DO NOT OPEN

CAUTION

:  TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

This symbol indicates that dangerous voltage consisting a risk of electric shock is 
present within this unit.

This exclamation point symbol is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING

To reduce the risk of fi re or electric shock, do not expose this appliance to rain or moisture.

WARNING

Be sure to use only the standard adapter that is specifi ed in the specifi cation sheet.
Using any other adapter could cause fi re, electrical shock, or damage to the product.

Incorrectly connecting the power supply or replacing battery may cause explosion, fi re, electric shock, or damage to 
the product.

Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fi re.

Securely plug the power cord into the power receptacle. Insecure connection may cause fi re.

When installing the controller, fasten it securely and fi rmly. The fall of controller may cause personal injury.

Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers fi lled with water on top of the 
controller. Doing so may cause personal injury due to fi re, electric shock, or falling objects.

Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fi re or electric shock.

If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the 
power source and contact the service center. Continued use in such a condition may cause fi re or electric shock.

If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in 
any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.)

. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.

CAUTION

Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive 
vibration or magnetic interference.

Do not install in a location subject to high temperature (over 50°C), low temperature (below -20°C), or high humidity. 
Doing so may cause fi re or electric shock.

If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it.

Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fi re or damage 
to the product.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

1.

2.

3.

4.

Summary of Contents for SSA-S1000

Page 1: ...dalone RFID Access Controller user manual SSA S1000 imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com ...

Page 2: ... injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers filled with water on top of the controller Doing so may cause personal injury due to fire electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause fire or electric shock If any unusual smells or smoke come from the unit stop using the product In such case ...

Page 3: ...y If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with cart stand tripod bracket or table specified by the manufactu...

Page 4: ...STALLATION AND EXTERNAL CONNECTION 9 9 Installation 9 Bypass Diode Connection 10 I O Connection SYSTEM INITIALIZATION BASIC OPERATIONS 12 12 Initializing the system by short circuiting 12 Basic Operations 13 To register delete Master ID 13 To register delete ID card PRODUCT SPECIFICATIONS 15 15 Product Specifications ...

Page 5: ...le method to register or delete cards and initialize the system which is one of the most convenient and safest door controller And it is also featured by the 2 color LED indicator and the internal buzzer enabling you to easily check the current mode and operation of the door lock 125 kHz Proximity Access Controller Up to 512 users including one Master ID can be registered Standalone no application...

Page 6: ... S INCLUDED Check if the following items are included in the product package t Gj Main Module Bezel Master Card x1 Keytag x5 x Gn 3 5 x 40mm Screws x2 3 5 x 25mm Screws x2 6 x 30mm Plastic Anchors x2 Diode X 2 UF4004 1N4001 4007 Quick Guide CD Manual ...

Page 7: ...1 LED Displays the system operation status using red and green indicators 2 Fixing Hole Fixing hole for wall mounting 3 Connection Cable Used to connect to the power or I O cable 4 Program Port Port used to upgrade the firmware 5 Buzzer Piezo buzzer 5 4 3 ...

Page 8: ...n Exit Button Connection Port Output Purple Alarm Out Alarm Device Connection Port White Door Lock Out Door Lock device connection port Not used Gray Orange Brown CABLE SELECTION Item Cable Type 1 Power DC 12V Belden 9409 18 AWG 2 Conductor Unshielded Belden 9409 18 AWG 2 Conductor Unshielded 2 Door Contact Sensor Exit Button Sensor Input Belden 9512 22 AWG 4 Conductor Shielded Belden 9514 22 AWG ...

Page 9: ...reader module cable into the center hole and secure the module using two screws inserted in the upper right and the bottom left corner respectively Insert the bezel of SSA S1000 into the reader module and attach it by pressing the upper and lower corner of the bezel BYPASS DIODE CONNECTION If you connected an inductor door lock or alarm device to the output relay there should occur a voltage surge...

Page 10: ... black line To connect the Door Contact Sensor Connect the COM port of the sensor to the blue line Connect the NO port of the sensor with the GND line To connect the Exit Button Connect one end of the button to the green line Connect the other end of the button to GND 1 2 1 2 1 2 PUSH DOOR CONTACT blue EXIT BUTTON green GND black DC 12V red GND DC 12V DC 12V POWER Exit Button Door Contact Sensor ...

Page 11: ... of the lock device to the white line To connect the alarm device Connect the plus line of the alarm device to DC 12V Connect the minus line of the alarm device to the purple line To specify the lock type POWER FAIL SAFE Connect the yellow line to GND POWER FAIL SECURE Leave the yellow line in the floating state 1 2 1 2 1 2 DOOR LOCK OUT white ALARM OUT purple Door Lock Alarm Device Cathode Anode 1...

Page 12: ...at turning ON OFF twice before being completely turned OFF In the power off condition all LED indicators turn red bottom up in sequence You will hear a beep once When you present a registered card to the product or press the Exit button All LED indicators turn from red to green and turn off top down in sequence before turning back red Then the door stays open for the specified time with the upper t...

Page 13: ...s the Master Card TO REGISTER DELETE ID CARD If you present the Master Card to the product it will sound the beep once and the first three LED indicators from the top will turn green from the top If you present a new user card to the product it will sound the beep once and all of the LED indicators except for the first three ones from the top will turn from red to green Then they all turn off and tu...

Page 14: ...d g For deleting the ID once the Master Card is registered refer to the ID registration and deletion section in this manual h Turn off the product and short circuit the purple and blue lines then turn the product back on i The Master ID will be deleted with a flashing LED indicator and beep j When the Master card is deleted turn off the product and restore the purple and blue lines to their respect...

Page 15: ...or Sensor Lock Type Select Power fail Safe Power Fail Secure Output Port 2ea TR Output DC 12V Rating Max 300mA Alarm Output DC 12V Rating Max 1A Lock Output LED Indicator 9 LED Indicators Red and Green Beeper Piezo Buzzer Operating Temperature 20 C to 50 C Operating Humidity 10 to 90 Relative Humidity Non Condensing Color Material Silver with Black Polycarbonate Dimension W x H x D mm 45 0 x 122 0...

Page 16: ...Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environ...

Reviews: