English
_ 11
INSTALLATION AND EXTERNAL CONNECTION
SSA-R2000V
EXTERNAL CONNECTION
WIRING DIAGRAM
Category
Cable Wiring
Power Supply Unit
Connect the DC+12V to the red line.
Connect GND to the black line.
Wiegand Connection
Connect the green line of the product to the Wiegand D0 input port of the controller.
Connect the white line of the product to the Wiegand D1 input port of the controller.
LED Control
Enables you to turn on or off the LED indicators.
To control the green indicator, connect the yellow line; to control the orange indicator, connect the blue line
with white stripes, to the output port of the controller. (see page 12)
Buzzer Control
Enables you to turn on or off the buzzer.
To control the buzzer, connect the blue line to the controller’s output (relay). (see page 12)
Tamper Control
Connect the COM port (Pink line) of the product’s tamper switch to GND; connect the NC port (Light yellow)
of the tamper switch to the input port of the controller.
RS-232 Connection
Connect to the COM port of the PC. (Connect pin 2 of the DB-9 connector to the purple line; connect the
orange line to pin #5 of the DB-9 connector)
Wiegand Data 0 Out
Wiegand Data 1 Out
PC
POWER
CONTROLLER
SSA-R2000V
Red
Black
DC +12V
GND
RS-232(GND)
RS-232(TX)
Purple
Orange
Tamper Switch Out(NC)
Tamper Switch Out(COM)
Buzzer Control In
LED Control In(Green)
LED Control In(Orange)
Green
White
Light yellow
Pink
Blue
Yellow
Gray