- 25 -
6-2 Error Code Numbering Rule(continued)
Error Code List
Gas Sensor
Temp Sensor
Weight Sensor
Easy/Ph Sensor
Error Code
Gas Sensor Error Case (E-1X)
E-11
Open
E-12
Short
E-13
T1 Max Time Error
E-14
Dry Up / No Load
Error Code
Temp. Sensor Error Case (E-2X)
E-21
Open
E-22
Short
E-23
T1 Max Time Error (Preheating not completed)
E-24
Over temperature error
E-25
In case abnormal temperature is sensed at Micro Cook
E-26
In case the temperature is not over the fixed AD in first
3 minutes after cooking by heater starts.
Error Code
Gas Sensor Error Case (E-1X)
E-31
Open (When value of HEX is above “FF” for 5 seconds)
E-32
Short
E-33
In case the initial value of HEX is under “14” for 30
seconds while a weight sensor in operation.
E-34
In case the initial value of K calculated by a weight
sensor is above and under “±28” as value of HEX.
E-35
In case the value of A is “-” as a weight sensor
calculates.
E-36
In case the door opens during sensor cooking.
Error Code
Easy/PH Sensor Error Case (E4)
E-41
Open
E-42
Short
E-43
T1 Max Time Error
E-44
Dry Up
E-45
Cooling Error (3minutes)
E-46
Primary Open Error(3minutes)
E-47
The door opens during cooking