background image

CN05 Gas Sensor      
3-

4 5vdc                     

CN202 Pwr & Relay                                                      

1-(CN201-1) Main                             
3-(CN201-1)  TT                               
5-(CN201-1)  Vent Low                               
7-(CN201-1)  Vent High                         
9-(CN201-1)  Vent Boost                                              

Main PCB 

CN201 Relay, Lamp, SMPS                                        

1 Line 1                                                                           
3-1 RY202 In Rush Relay Neutral Contact            
5-1 RY206 Bright Lamp Relay Neutral Contact   
5-1 RY205 Night Lamp Relay Neutral Contact  
7-1 RY207 Louver                                                 

RY203

 

Power 
High Relay 

RY209             

 

Fan 

RY208

 

TT 

RY201

 

Main 
Relay 

RY05       

Night            
Relay 

RY206             

Bright                   
Relay 

RY202

 In 

Rush Relay 

Door Interlock Ass’y 

CN401

 

Door Connector                  

1 Door sw                                    
3 Door sw                                    
3-5 12vdc                                      
4-5 5vdc            

The fuse is located on the noise filter. 

1. 

Disconnect power and remove grille and Assembly 

Control Box. 

2. 

Replace the fuse. 

3. 

When 20A fuse blows out by the operation of interlock 

monitor switch failure, replace the primary interlock 
switch, secondary interlock switch, door sensing switch, 
interlock monitor switch and power relay. 

4. 

When the above four switches operate properly, check 

if any other part such as the control circuit board, blower 
motor or high voltage transformer is defective. 

CN01               
1) KEY OUT-1              
2) KEY OUT-2                
3) KEY OUT-3            
4) KEY OUT-4 
5) KEY OUT-5 
6) KEY OUT-6 
7) KEY OUT-7 
8) KEY OUT-8 
9) KEY OUT-9 
10) KEY IN-1 
11) KEY IN-2 
12) KEY IN-3 
13) KEY IN-4 
14) KEY IN-5 
15) KEY IN-6 
16) KEY IN-7

 

RY207

 

Louver 

RY204

 

Power Low 
Relay 

Reviews: