Checking Feeder line Connection
After connecting the feeder line, perform the continuity test and feeder cable return loss to
check if the feeder cable is changed and measure VSWR of antenna and feeder cable.
Take measurements for the sections
- for all of the cables.
The standing wave ratio must be equal to or less than the reference value. If not, the cable
must be removed, measured for each section again, and necessary actions be taken.
VSWR Standard
The standing wave ratio (VSWR) of the cable and connector between the system’s
RF port to the antenna port must be smaller than 1.5 (return loss: 14 dB).
If a separate standard has been established with the career, the established
standard will take precedence.