Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
8. Level 3 Repair
8-4-16. Display
LCD is still off after PWR ON
Yes
No
No
Reconnect the SOC7004
END
Yes
No
Check
VDD_LCD_3P0 = 3.0V (C7081)
VDD_LCD_1P8 = 1.8V (C7082)
No
Resolder or Replace the U7002(3.0V)
Resolder or Replace the U7003(1.8V)
Yes
No
Check
ELVDD 4P6 = 4.6V (C7079)
ELVSS_-4P4 = - 4.4 ~ - 1.4V (C7078)
ELAVDD_7P3 = 7.6V (C7080)
No
Resolder or Replace the U7038
Yes
No
Check the connection of
SOC7004
Replace the Display module
Yes
No
Replace the Display con-to-con FPCB
Yes
No