background image

English

 

_3

When used outside of the U.S., it may be used HAR code with fittings of an approved agency is 
employed.

CAUTION

These servicing instructions are for use by qualified service personnel only. 
To reduce the risk of electric shock do not perform any servicing other than that contained in the 
operating  instructions unless you are qualified to do so. 

Please read the following recommend safety precautions carefully.

Do not Place this apparatus on an uneven surface.

Do not install on a surface where it is exposed to direct sunlight, near heating equipment or heavy 
cold area.

Do not place this apparatus near.

Do not attempt to service this apparatus yourself.

Do not place a glass of water on the product.

Do not install near any magnetic sources.

Do not block any ventilation openings.

Do not place heavy items on the product.

User’s Manual is a guidance book how to use the products

The meaning of the using sign in the book is following

Reference: in case of providing information for helping of product’s usages

Notice: If there’s any possibility to occur any damages for the goods and human caused by not 
following the instruction 

Ú

  Please read this manual for the safety before using of goods and keep it in the safe place.

y
y

y
y
y
y
y
y

y
y

Summary of Contents for SIA-0010

Page 1: ...es not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the ...

Page 2: ...head symbol within an equilateral triangle is intended to alert the user to the presence of dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the liter...

Page 3: ...rect sunlight near heating equipment or heavy cold area Do not place this apparatus near Do not attempt to service this apparatus yourself Do not place a glass of water on the product Do not install near any magnetic sources Do not block any ventilation openings Do not place heavy items on the product User s Manual is a guidance book how to use the products The meaning of the using sign in the boo...

Page 4: ...t s Included Injection bracket x2 Injection Bracket Wing x4 Screw x4 Steel Bracket x2 optional User Manual Warranty Card U shaped Bracket x2 optional Power LED Terminal Good LED Response Time Control Wheel Sight Window Lens Vertical Angle Adjustable Screw Alarm LED Temper Monitor Jack ...

Page 5: ...expose it to a place where its light projector or light receiver is affected by a direct strong light such as sunlight or headlight below 2 is not allowed in the optical axis Do not install it in an unstable not properly secured place wire fence or unsecured pole is not allowed Do not install it in a place where the infrared light is blocked due to a seasonal reason such as thick wood or bushes Ke...

Page 6: ...pull out the cables through the hole When done adjust the optical axis and insert the cover To attach to the pole Pull out the cables from the wiring hole of the pole insert the U shaped pole bracket to the pole Attach the sensor to the bracket and arrange the cables as necessary same as in wall mounting 3 4 5 1 2 Rubber Hole Cable In Hole Pole bracket Optional Pole bracket Optional ...

Page 7: ...You can use the left right adjustable screw and the vertical adjustable screw of the reflector to refine your adjustment vertically 10 horizontally 90 Check the level of the light received from the monitor output signal You can use the tester to measure the DC voltage and refine your adjustment Check the output voltage of the tester and close the cover Output Voltage Optical Axis Status 3 0V or highe...

Page 8: ... transmitter and receiver The cover of the transmitter or receiver has impurities on it 1 2 3 Adjust the optical axis as necessary Remove the obstacle Wipe out the impurities with a soft cloth 1 2 3 The alarm sounds intermittently Disconnected cables Fluctuation of the power voltage There exists an obstacle between transmitter and receiver There exists a different strong power source around the tr...

Page 9: ... AGC Voltage Alarm 2 0V or less Ready 2 1 2 9V Good 3 0V or higher Current Consumption Receiver 19mA Transmitter 22mA max Alarm Out Dry contact relay output 1C COM N C N O Reset Interruption time off relay approx 1 sec Temperature 25 C 60 C Temper Output Dry contact Micro SW COM N C Adjustment of Optical Axis Horizontal 180 90 vertical 20 10 Bracket Type Default Wall mount bracket Optional Pole mo...

Page 10: ...ble harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environme...

Reviews: