Registration
Button :
This button is used to change Master PIN Code/User PIN Codes/User Cards or the
lock settings. It is found below the battery cover of the Interior Unit. The length of time the
[Registration]
button is pressed varies depending on the function.
Resetting :
Deletes all registered information and restores the factory default. After resetting, change the
Master PIN Code for security.
Restart Button :
This button resets the lock when the lock stops functioning. Registered information is not
deleted.
Sound Setting :
The volume during the input of numbers and opening or locking of the door can be set
from Level 0 ~ Level 2. The sound is muted at Level 0 and is at maximum volume at Level 2. The registration
mode operates at Level 1 regardless of the sound setting.
User Card :
You can register up to 70 User Cards including the User PIN Codes. You can open the door
with a User Card.
User/Management Number :
It is the same number as the registered user’s address and can be set
from 1 to 70. The User Number should be managed with caution as it is used to register or delete User PIN
Codes/Cards.
User PIN Code :
You can register up to 70 User PIN Codes (4-12 digits) including the User Cards. You can
open the door with a User PIN Code.
Wake Up Button :
Pressing this button activates the number pad. Enter the PIN Code or touch with the
Card while the number pad is illuminated. It is also used to quit the registration mode.
Scope of Master, User Settings
Factory Defaults
Function
Factory Defaults
Master PIN Code
1234
Volume
Level 1
User PIN Code/Card
None
Locking Mode
Auto
Out-of-home Security Function
Disabled
Double-locking
Disabled
Random Security
Enabled
Double Authentication Mode
Disabled
Infrared Ray Sensor
Disabled
Settings
Master
User
Opening the Door
Setting Up the Sound
Changing Master PIN Code
Registering User PIN Code/Card
Deletion of User PIN Code/Card
Setting the Locking Mode
Setting Out-of-home Security
Setting Double-locking
Setting Random Security
Factory Reset
Setting the Infrared Ray Sensor
Setting the Double Authenti-
cation Mode
Summary of Contents for SHS-3420
Page 23: ...23 Drilling Template Sheet for 60mm Backset ...
Page 24: ...24 Drilling Template Sheet for 60mm Magnet 69 0 69 0 2 0 ...
Page 26: ......
Page 27: ......