background image

~

Item

Specifications

Voltage

AA Alkaline 1.5 Batteries (LR6) 4EA or 8EA (6V)

Emergency 

Power

Source

9V Battery (6LF22) (Separately sold)

Operation 

Method

Electronic Control Method (Password entry or card or 

key tag reading)

Weight

4.1 kg (including both inner and outer bodies)

Product

Dimensions

Outer Body

(including 

the handle)

88.1mm (W) X 392.4mm(H) X 64.5mm(D)

Inner Body

(including 

the handle)

88.5mm (W) X 357.6mm(H) X 69.3mm(D)

Double authorization mode requires both card and password to open the  
door, ensuring more security. 
To setup the double authorization mode, more than 1 card must be registered.

Battery Replacement Alarm Generation

If the melody of “Blues for Elise” sounds when opening the door with the 
password or a card (key tag), it is time to replace the batteries.
(The low battery indicator is lighted when the melody sounds.)

Replacing the Battery

Replace all 8 batteries within a 1 week of the first alarm sound.
- The unit will stop operating suddenly if the batteries are not replaced.

If the batteries are not replaced after their replacement time comes, they will 
be completely discharged and the lock will not operate.

Purchase an emergency battery (9V) at the nearest store. 

-  As the alkaline batteries offer longer life, they are recommended over the 

manganese batteries or rechargeable ones.

Place the card or key tag on the card reader, or enter the password, while 
the 9V battery is connected to the external power port of the outer body.

This function generates the alarm sound when fire is detected so that the 

residence can quickly respond. The built-in fire detection function is a basic 

function of the lock, and cannot be released by the user.

Fire detection function is operational at about 70 °C ± 10 °C; this can vary 

depending on the installation environment.

When fire occurs, the temperature sensor detects it and flashes the [Close] button 

while generating the alarm sound.

The door is automatically opened after the alarm sound has stopped.

(The lock resumes normal operation if the inside temperature returns to

a normal level.)

The built-in fire detection function is activated when the temperature rises around 

60°C, which may differ depending on the installation environment.

  

The contents of this user guide are subject to change without prior notice 
to the user in order to enhance performance of the product.

   Depending on battery manufacturer, date of manufacture and the user 

environment, the duration of use may vary. 
(In the case of average use, given as 10 times a day, 8 AA alkaline 
1.5Vbatteries can last for 10 months.)

  If the poles of the batteries are not placed properly, the lock will not 

operate normally.

  Liquid leaks from batteries can damage the product. Check the batteries 

regularly (every 6 months).

   After the battery replacement alarm has sounded, password/card 

information cannot be registered, changed, deleted, initialized or 
configured until the batteries are replaced.

Warning

10

11

12

7

8

9

Double Authorization Mode Setting

Replacing the Batteries

Using the Emergency Battery

Built-in Fire Detection Function

Product Specifications

You can set the security mode suitable for your use when you open the 
door using a password.

Briefly press the [Register] 
button on the inner body.

DING
DONG

[7] Button :  Multi-leveled Security 

Code Entry Mode

[9] Button : Common Mode

Press the [

] button after pressing the

[7] or [9] button, and the security mode
will be set.

DING DONG 
DENG

Multi-leveled Security Code Entry Mode Setting

The welcome function is a convenient function that automatically activates 
the authorization standby mode when a user approaches the door, even 
before touching the number pad.

Open the battery cover and 
press [Registration] button 
briefly.

DING
DONG

DING DONG 
DENG

Welcome Function On/Off

[1]+[

] button:  Welcome function on, the one-

minute alarm function on

[2]+[

] button:  Welcome function on, the one-

minute alarm function off

[3]+[

] button: Welcome function off

On and Off / Function Description

-  Welcome function on: The mode will automatically activate the authorization 

standby mode when a user approaches the door lock.

-  Welcome function off: The mode will authorize a user when the user enters the 

password on the number pad or connects a card to the number pad. 

-  One-minute alarm function on/ off: When someone remains in front of the  door lock 

for more than a minute, this mode will sound the tamper prevention alarm.

 

  The factory defaults are set with the welcome function on and the alarm 

function off.

  

 The working distance of the infrared sensor can differ depending on light 

conditions and other environments. When the front door is exposed to 

sun light or constant bright lights it is advised to limit the usage of the 

sensor as it might sound the alarm.

Caution

This function generates the alarm sound when an attempt is made to forcefully 
open the door from the inside or the outside.
(This is a basic function of the lock, and cannot be separately set or released.)
If the door is forcefully opened while locked, the door opening sensor  
detects it and generates the alarm sound.

Intrusion Detection Function

This function sets the time interval between the moment the door open/closed 

sensor recognizes the door as closed and the moment deadbolt locks the door.

In an environment that the door closes slowly and the deadbolt jams before the 

door is fully closed, the situation can be fixed by adjusting the door lock time.

Open the battery cover of the 
inner body and briefly press the 
[Register] button.

Door Lock Time Setup Function

DING
DONG

Press [51] ~ [59] button, and then press  
[

] button.

Default: 1 second

[51] : 1 second

[59] : 9 second 

Briefly press the [Register] 
button on the inner body.

DING
DONG

[4] Button :  Double authorization 

mode on

[6] Button :  Double authorization 

mode off

Press the [

] button after pressing the

[4] or [6] button, and the authorization

mode will be set.

DING DONG 
DENG

Two-factor Authentication Mode Operation

Touching 

[Number Pad]. 

Enter the password 

when the number pad is 

lighted, and press the [

button.

Touch the card on to 

the [Card Reader], if the 

authentication is successful, 

the door will open.

Success:
DING DONG DENG
Fail:  DING DONG 

DING DONG

Success:
DING DONG 
DENG DONG
Fail:  DING DONG 

DING DONG

CARD

The sound that is generated when the number buttons are pressed, when the 
door is locked or when the locked door is unlocked, can be set according to 
the user’s preference. The product is set to generate all sounds at the factory.

- [ 0 ] Button: All sounds except the alarm sound are deactivated. 
-  [1] and [2] Buttons: All sounds are activated and the sounds get bigger as the step 

become higher.

Sound Setting and Releasing

The Automatic Locking mode allows for automatic locking of the door 
when it is closed.

- Automatic: The door is automatically locked 1 seconds after being closed.
-  Manual:  The door does not lock automatically, and [CLOSE] button must be 

pressed from the inside, touch [Number Pad] to close the door.

Automatic/Manual Locking Setting

Open the battery 

cover on the 

inner body.

Put the [Sound Control] 

switch on one of [0], [1], or 

[2], and close the battery 

cover.

~

Set the [Automatic/Manual 

Locking] toggle switch of 

the Inner Body to the ‘A’/‘M’ 

position.

Open the battery 

cover on the inner

body.

~

Opening the Door Using an Emergency Battery

Inside:  Press the [CLOSE] button, then the 

sound for action-unavailable willbe 
heard.

Outside:  Press the [Number Pad] or touch with 

a card, then the sound for action-
unavailable will be heard.

At-home security mode is to prevent opening of the door from outside while 

someone is inside.

Security Assurance Mode Operation

While the door is locked, press 
[CLOSE] button on the inner body 
part for 3 seconds.

Security Assurance Mode 
Activation

Security Assurance Mode Deactivation

Rapid beeping

DING DONG 
DENG

Or

Security Assurance Mode Activation/Deactivation

DING DONG 
DENG DONG

~

~

   When the security assurance function is activated, the door cannot be 

unlocked from the outside, so please be careful. Be especially careful not 
to allow children to set this mode accidently from the inside.

Warning

This function generates an alarm sound and deactivates lock operation  
when it is improperly handled from the outside.

This alarm will sound if an attempt is made to open the door with an invalid card, or if 

a wrong password is entered five times in a row.

The alarm sound is generated, and the lock is deactivated for 3 minutes. While the 

door is in this inactive mode, a single “DING” sound is generated every 10 seconds 

and seven consecutive “DINGS” will sound after 3 minutes. Following this, the lock is 

released from inactive mode.)

Press the [Register] button.

Outside

Apply the registered card or key tag to the card reader, or enter the 
password and then press the [

] button.

Inside

Releasing the Alarm

Alarm Sound (Prank Prevention Function)

Set up Instructions for Alarm and Anti unlock functions

Alarm function 

When this function is activated, an alarm sound and light will turn on for 

approximately 5 minutes duration.

Anti-Bypass function

When this function is activated, the internal handle will become tightened to 

prevent bypass attempts through door edge tools will be minimized.

When the door is closed, user can set 

up the alarm function by pressing and 

holding the [   ] button for 3 seconds 

until sound confirmation.

Press [

] and hold. 

After 3 seconds, the alarm will be 

come active. 

DING DONG DENG

Set up the Anti-Unlock function

Set up the Alarm function

CARD

Or

  

Anti-Bypass function should only be set up when there is no one inside. 

DING DONG DENG

Release the Alarm function

Touch the keypad to turn on.  

Present a registered RF tags/card or 

password and press [

] to release.

~

BEEP BEEP BEEP ~

Release the Anti-Bypass function

Press the [CLOSE] button to release the 

internal handle from Anti-Bypass function.

When this function is active, it may be 

harder to pull the internal handle for elderly 

or children to open the door from inside.

Warning

Password Change

The password can be 4~12 digits number. Only one password can be registered. 

Enter the current password (‘1234’ after 
initialization) when the number pad is lighted, 
and press the [

] button.

DING DONG

1.  Pressing the [Register] Button 

(from the inside)

Open the battery cover of the inner 
body and briefly press the [Register] 
button.

2.  Entering the Current Password 

(from the outside)

DING DONG 
DENG, DING 
DING

Enter the new password (4 to 12 digits) 
and press the [

] button.

3.  Entering a New Password  

(from the outside)

DING DING DENG

  

Manage your password with care so that unauthorized people will not 
have access to it. Regularly changing your password can reduce the risk 
of it being leaked.

Warning

To make sure the password has been  
properly registered, check the new password 
and close the door.

4.  Checking New Password 

Operation (from the outside)

DING DONG 
DENG DONG

You can delete all registered cards.

Deleting Registered Cards

Enter the current password when the 
number pad is lighted, and press [

] button. 

DING DONG

 

DING DING

1.  Pressing the [Register] 

Button (from the inside)

Open the battery cover of the inner 

body and briefly press the [Register] 

button for 3 seconds.

2.  Entering the Current Password 

(from the outside)

DING DONG DENG

Pull the inner body handle 

to open the door, and it will 

deactivate.

If the number pad is lights, enter ‘88’ and 
press [

] button.

3.  Entering the number  

(from the outside)

DING DONG DENG

Reviews: