Samsung Electronics
4
1. AUTO MODE : In this mode, operation mode(COOL,
HEAT) is selected automatically by the room temperature
of initial operation.
√
√
In case of Heat pump model.
√
√
In case of Cooling only model.
∆
T= -1°C, -2°C, 0°C, +1°C, +2°C
∆
T is controlled by setting temperature up/down key of
remote control
2. COOL MODE : The unit operates according to the
difference between the setting and room temperature.
(18°C~30°C)
3. HEAT MODE(In case of Heat pump model) :
The unit operates according to the difference between the
setting and room temperature.(16°C~30°C)
*Prevention against cold wind : In order to prevent the
cool air from flowing out at the heat mode, the indoor fan
does not operate or operates very slowly in the following
cases. At this time, the indoor heat exchanger will be
preheating.
- For 3~5 minutes after the initial operation
- For deicing operation
- The operation of an indoor fan in accordance with the
temperature of an indoor heat exchanger
*High temperature release function : It is a function to
detect an outdoor overload by the sensor of an indoor
heat exchanger and to turn the outdoor fan or the
compressor ON/OFF for safety.
*Deice : Deicing operation is controlled by indoor unit's
heat exchanger temperature and accumulating time of
compressor's operation.
Deice ends by sensing of the processing time by deice
condition.
4. DRY MODE : Has 3 states, each determined by room
temperature.
The unit operates in DRY mode.
*Compressor ON/OFF Time is controlled
compulsorily(can not set up the fan speed, always
breeze).
*Protective function : Low temperature release.
(Prevention against freeze)
5. TURBO MODE : This mode is available in AUTO, COOL,
HEAT, DRY, FAN MODE.
When this button is pressed at first, the air conditioner is
operated "powerful" state for 30 minutes regardless of the
setting temperature, room temperature.
When this button is pressed again, or when the operating
time is 30 minutes, turbo operation mode is canceled and
returned to the previous mode.
*But, if you press the TURBO button in DRY or FAN
mode that is changed with AUTO mode automatically.
6.
SLEEP MODE : Sleep mode is available only in COOL or
HEAT mode.
The operation will stop after 6 hours.
*In COOL mode : The setting temperature is automatical-
ly raised by 1°C each 1hour When the temperature has
been raised by total of 2°C, that temperature is
maintained.
*In HEAT mode : The setting temperature is automatically
dropped by 1°C each 1hour.
When the temperature has been dropped by total of 2°C,
that temperature is maintained.
7. FAN SPEED : Manual (3 step), Auto (4 step)
Fan speed automatically varies depending on both the
difference between setting and the room temperature.
8.
COMPULSORY OPERATION :
For operating the air conditioner without the remote
control.
*The operating is the same function that AUTO MODE in
the remote control.
9.
SWING : BLADE-H is rotated vertically by the stepping
motor.
*Swing Set : Press the
button under the remote
control is displayed on LCD the
and the blades
move up and down. If the one more time press the
button, blades location is stop.
below 28˚C
28˚C~below 34˚C
34˚C~below 40˚C
above 40˚C
The temperature of
indoor heat exchanger
Indoor fan speed
off
LL Speed
L Speed
Setting Speed
Operation Type
Room Temp.
Cool Operation
Tr
≥
25°C+
∆
T
Compressor ON
Tr
≥
24°C+
∆
T
Compressor OFF
Room Temp
Operation Type
Tr
≥
21°C+
∆
T
Cool Operation (Set Temp:24˚C+
∆
T)
21°C+
∆
T>Tr
Heat Operation (Set Temp:22˚C+
∆
T)
2-2 Details for Operation Property
DB98-21337A(1) 05/1/4 2:19 AM Page 4
Summary of Contents for SH07AWH