SAMSUNG Proprietary-Contents may change without notice
SGH-S341i Flow Chart of Troubleshooting
2-
15
This Document can not be used without Samsung's authorization
F502 CHECK
pin13 ≥ -65dBm ?
3. PCS RX
CONTINUOUS RX ON
RF INPUT : 660CH
AMP : -50dBm
NORMAL CONDITION
catch the channel?
CHECK
ANT501,R509 contact ?
U501
pin 9, 32: 2.8V ?
F502 CHECK
pin5,6 ≥ -65dBm ?
U501 CHECK
pin16,17 ≥ -65dBm ?
C518,CN403
resolder or change
F502
resolder or change
C535,C536,L505
resolder or change
U102 pinA13, C127
change or resolder
U501 CHECK
pin 8 : 13MHz ?
Vp-p : 950mV?
OSC501
change or resolder
U501
resolder or change
U102 CHECK!!
U501
pin1,2,3,28 Vp-p
: 120mV ?
NO
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
F502 CHECK
pin12 : 2.8V
YES
U102
check & change
NO