![Samsung SGH-E730 Service Manual Download Page 58](http://html.mh-extra.com/html/samsung/sgh-e730/sgh-e730_service-manual_356819058.webp)
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Flow Chart of Troubleshooting
7-34
7-18. PCS Receiver
Module1 pin8
>= -65dBm
Resolder CN100, C101
No
Yes
RX ON
RF input : 661CH
Amp : -50dBm
Check Module1
pin9= H
pin10, pin12 = L
Module1 pin5, pin6
>= -65dBm
U100
B1 >= -70dBm
A1 >= -70dBm
Check ANT Switch
control circuit
Resolder Module1
Resolder C115, C116, L108, L109
Yes
Yes
Yes
No
No
No
END
U100 H7,H8,J7,J8
>= 1V
Check U100
J2,A6,B6,A9,E9
>=2.7V
Check & Resolder
U100, R114, R116
RF26MHz, RF PSU Part
Resolder U100
C219, C220
>= 1V
Yes
Yes
Yes
Yes
No
No
Check U200