SAMSUNG Proprietary-Contents may change without notice
SGH-C120 Flow Chart of Troubleshooting
2-
21
This Document can not be used without Samsung's authorization
2-2-4. DCS TX
F101
pin 11 :
about 2~3
dBm?
C103,RFS100
check&change
F101
pin2 : 2.8 V?
U300
check & change
PAM100
pin16
: about
4~5dBm?
F101
check & change
PAM100
pin4 : 3.7 V?
NO
NO
YES
YES
YES
NO
NO
BATTERY
check & change
PAM100
pin 6 : 1.4V ?
YES
NO
PAM100 pin1
about : -5dBm ?
YES
PAM100
pin 3 : 3V?
YES
YES
PAM100
change or resolder
NO
U300
check
U300
check
NO
U100
pin12,13,25,26,
28 : 2.8V ?
U300
pinA13,
C314
change or resolder
YES
U100
pin30, 31 :
26MHz ?
Vp-p : 950mV?
U100
pin4,5,6,7:100m
V?
YES
U300
change or resolder
NO
NO
U100
change or resolder
YES
NO
OSC100
change or resolder
CONTINUOUS TX ON CONDITION
CH : 698CH(DCS)
TX POWER CODE: 520 CODE Aplied
RBW : 100KHz
VBW : 100KHz
SPAN : 10MHz
REF LEV. : 10dBm
ATT. : 20dB
①
⑤
③
④
②
⑦
⑥