background image

 

Samsung ER 5200 Series 

SAM52

 

User's Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CRS, Inc. 

2909 Anthony Lane 

Minneapolis, MN  55418 

(612) 781-3474 

All specifications are subject to change without notice 

2003, Cash Register Sales, Inc. 

Summary of Contents for SAM52

Page 1: ...Samsung ER 5200 Series SAM52 User s Manual CRS Inc 2909 Anthony Lane Minneapolis MN 55418 612 781 3474 All specifications are subject to change without notice 2003 Cash Register Sales Inc ...

Page 2: ... a result of improper installation maintenance or repairs not made by CRS unauthorized modification or as a result of removal improper use abnormal operation by the buyer or any other misuse or mistreatment of the goods EXCLUSIVITY OF WARRANTY THE WARRANTY CONTAINED HEREIN IS EXPRESSLY IN LIEU OF ANY OTHER EXPRESSED OR IMPLIED WARRANTY INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS F...

Page 3: ...op Down List Boxes 8 Check Boxes 8 Option Buttons 8 Scrolling 8 Interface Specifications 9 Menu Functions 10 Stores 10 Creating a New Store 10 Selecting the Default Store 12 Editing Store Information 13 Deleting A Store 13 Edit ECR Data 15 PLU File 16 Group 21 Tax 22 System Options 23 Print Options 24 Function Keys 25 Clerks 26 Logo Description 27 Financial Messages 28 Clerk Messages 29 NLU 30 Tar...

Page 4: ...s 53 Copy a Store 53 Copy PLU File 54 After Polling 55 Set Auto Poll 56 Length of Polling Time 57 Backup Poll Data Files 57 Design 5200 Keyboard 58 Design Generic Keyboard 59 Quit 60 Appendices 61 Structure Of Stores 61 File Definitions 62 Sam52 PLU File Structure 62 Structure Of Polling Files 64 Sample Reports 66 Financial Report 66 Time Report 67 PLU Report 68 Clerk Report Data for One Clerk Onl...

Page 5: ...he PC Download bitmap images for custom pre post logos Poll reports from the register save display or print them at the PC Poll all stores or individual stores Poll unattended at a predetermined time Download preamble postamble bitmap files SAM52 converts polled reports to ASCII files ready to be used by other PC applications Requirements To use this utility you must have Pentium 100 or faster CPU...

Page 6: ...Windows Desktop choose the My Computer icon 3 Select your CD ROM drive usually drive D 4 Choose Setup the Welcome dialog displays 5 Click Next the Ready to Install dialog displays 6 Click Next the Install Directory dialog displays 7 Click Next the Select Shortcut Folder dialog displays 8 Click Next When all files are copied the Finished dialog displays 9 Click Finish 10 Click OK to restart your PC...

Page 7: ...hart RS 232C option chart that follows 4 Enter 1 the value for PC and press the CASH key 5 Press CASH to exit the program RS 232 Option Chart Address Option Value Selection 0 9600 BPS 1 1200 BPS 2 2400 BPS 3 4800 BPS 1 Baud Rate 4 19200 BPS 0 NONE 1 ODD 2 Parity 2 EVEN 0 8 BITS 3 Data Bits 1 7 BITS 0 1 BIT 4 Stop Bits 1 2 BIT 0 NONE 1 PC 2 SCALE 4 Receipt Printer 5 Not used 7 COIN 5 Device Functio...

Page 8: ...ON 12 Display Type 1 ICD Preparing the ER 5200 for Communicatons The register must be ready for communications Connect the register directly to the PC with the appropriate cable See Cabling Diagrams on page 71 The register power must be on A clerk must be signed on The register cannot be inside of a transaction The key lock can be in any position It is not necessary to manually place the register ...

Page 9: ...am52 exe 2 The SAM52 main screen displays YOU MUST DO THIS FIRST Before you can attempt communications or editing you must create at least one store Refer to Creating a New Store on page 10 After creating a store you must Receive Upload information from the ECR Refer to Receive Programs from ECR Upload on page 39 ...

Page 10: ... Keyboard You can choose a menu menu item or a command by clicking on it with your mouse Viewing Menus and Selecting Menu Items 1 Point at a menu item with your mouse 2 Point at your choice on the menu and click the left mouse button Menu Item Menu Choices ...

Page 11: ... Manual Introduction 7 Cascading Menus 1 The arrow indicates additional choices cascade from the first menu 2 Move the mouse pointer in the direction of the arrow to display additional choices Arrow Cascading Menu ...

Page 12: ...are provided Check Boxes Click on a check box to make a selection Click the check box again to deselect the item Option Buttons Click on one of the option buttons also called radio buttons to make a selection Your previous selection will pop up when a new selection is made Scrolling Move the scroll box to select the item you wish to work with Drag the scroll box or click the scroll arrows to find ...

Page 13: ...rface Specifications Communications Specifications Asynchronous Operation Communication Mode Half Duplex Baud Rate Select 2400 4800 or 9600 BPS Signal Level RS 232C Character Bits 8 Parity Bits None Stop Bits 1 Error Detection Data sum check ...

Page 14: ...tions Stores A store must be created before any communications or editing can take place Creating a New Store 1 Choose Create New from the Store menu to create a store You can create an unlimited number of stores The Create New Store dialog displays ...

Page 15: ...re O Select the Deactivate This Store check box if you wish the store to be inactive Modem Time Out Value R Unless otherwise indicated the default value of 99 will be entered automatically when the store is created Modem Initial String O This field is to allow you to enter any initialization required for your modem for polling or communications Do not add the command prefix AT in this string If yo...

Page 16: ...rop down list box to select the working store When you have created at least one store the list box will display all stores created The working store will display in the Default Store field All editing and programming will pertain to the selected working store Default Store Drop down list box ...

Page 17: ...he Edit Store Information dialog 3 Click Exit to save store information Deleting A Store 1 Choose Delete from the Stores menu to delete the working store from you hard drive A warning dialog displays 2 Click Yes to delete the store Caution This function will erase everything that pertains to this store Use extreme caution with this function Information that is deleted cannot be recovered ...

Page 18: ...ter s keyboard Detailed questions about the meaning of the register options are best answered by referring to the Samsung ER 5215 Operators and Program Manual or the Samsung ER 5200 5240 Operators and Program Manual Note If you did not Upload programs from the ECR you will get a message The file does not exist if you attempt to select any of these options Note If you wish to create a program for a...

Page 19: ...instructions on the screen or refer to the Samsung ER 5215 Operators and Program Manual or the Samsung ER 5200 5240 Operators and Program Manual for a complete description of your program options Choose PLU File from the Edit ECR Data menu The appropriate PLU Programming dialog box displays ...

Page 20: ...ssary use the scroll box to view the list of PLUs in the file Type a PLU descriptor in the Descriptor field and press ENTER or open the Descriptor drop down list box and click on the PLU you wish to edit If necessary use the scroll box to view the list of PLUs in the file With the list box open you can type the beginning letter or letters of a PLU descriptor and PLUs beginning with your entry will...

Page 21: ...rmation by clicking on the field and then entering new data If you are entering price data you must use the decimal key to enter cents Edit fields with check boxes such as the PRESET field by clicking on the field to add or remove a check 4 Click Save to save changes or click No Save to exit without saving changes Note For double wide Characters hold down the ALT key type 0253 then type the charac...

Page 22: ...en complete the remaining fields for the new PLU Fill fields requiring numeric information by clicking on the field then entering data If you are entering price data you must use the decimal key Fill fields with check boxes such as the PRESET field by clicking on the field to add or remove a check 3 Click Save to save changes or click No Save to exit without saving changes ...

Page 23: ...button 3 A warning dialog displays asking if you are sure you wish to delete the PLU 4 Click Yes to delete the PLU click No to abort the delete process Note To delete a PLU all totals Z1 and Z2 for that PLU must first be cleared PLUs will not be deleted at the register unless there is no register activity and deleted PLUs are downloaded ...

Page 24: ...m Manual for a complete description of your program options 1 Choose Groups from the Edit ECR Data menu The Group Programming dialog box displays 2 The current options for each group are displayed Use the scroll box at the right to view all of the groups use the scroll box at the bottom to view all of the options for each group Edit the descriptor field by double clicking on the field then type a ...

Page 25: ...options 1 Choose Tax from the Edit ECR Data menu The appropriate Tax Rates dialog box displays 2 Enter the tax you wish to program in the Tax field or open the Tax list box and select the tax you wish to program 3 Select the type of tax Add On Table VAT from the drop down list at the Tax Type field 4 Depending upon the type of tax selected the appropriate fields will be activated Enter a percentag...

Page 26: ...rogram options 1 Choose System Options from the Edit ECR Data menu The appropriate System Options dialog box displays 2 The current setting for each system option is displayed Use the scroll box at the right to view all of the system options Edit fields with drop down list boxes by opening the list box and selecting from the available options Edit fields with check boxes by clicking on the field t...

Page 27: ...program options 1 Choose Print Options from the Edit ECR Data menu The appropriate Print Options dialog box displays 2 The current setting for each print option is displayed Use the scroll box at the right to view all of the print options Edit fields with drop down list boxes by opening the list box and selecting from the available options Edit fields with check boxes by clicking on the field to a...

Page 28: ...screen to select the function key you wish to program 3 The options for the specific function key are displayed Make selections or changes as necessary Edit the descriptor field by clicking on the field then type a new descriptor Edit the Price Rate field by clicking on the field then entering a new price or rate whichever is appropriate Edit fields with drop down list boxes by opening the list bo...

Page 29: ...plete description of your program options 1 Choose Clerks from the Edit ECR Data menu The appropriate Clerk Programming dialog box displays 2 The selections for each clerk are displayed Make changes as needed Edit the descriptor field by double clicking on the field then type a new descriptor Edit fields with numeric information by double clicking on the field then enter new data 3 Click Exit to s...

Page 30: ... Operators and Program Manual or the Samsung ER 5200 5240 Operators and Program Manual for a complete description of your program options 1 Choose Logo Descriptor from the Edit ECR Data menu The appropriate Logo Programming dialog box displays 2 Use the scroll box at the right of the screen to view all of the logo descriptor fields 3 Edit the descriptor fields by double clicking on the field then ...

Page 31: ...ung ER 5200 5240 Operators and Program Manual for a complete description of your program options 1 Choose Financial Messages from the Edit ECR Data menu The appropriate Financial Messages dialog box displays 2 Use the scroll box at the right of the screen to view all of the descriptor fields 3 Edit the descriptor fields by double clicking on the field then type a new descriptor 4 Click Exit to sav...

Page 32: ...ung ER 5200 5240 Operators and Program Manual for a complete description of your program options 1 Choose Clerk Messages from the Edit ECR Data menu The appropriate Clerk Messages dialog box displays 2 Use the scroll box at the right of the screen to view all of the descriptor fields 3 Edit the descriptor fields by double clicking on the field then type a new descriptor 4 Click Exit to save change...

Page 33: ...umber PLU i e NLU key number one is PLU 1 However with this program you can assign any PLU number you wish to any one of the NLU keys 1 Choose Misc from the Edit ECR Data menu Then from the cascading menu choose NLU The appropriate NLU Programming dialog box displays 2 Use the scroll box at the right of the screen to view all of the NLUs 3 To edit an NLU type the PLU number you wish the NLU to add...

Page 34: ...msung ER 5215 Operators and Program Manual or the Samsung ER 5200 5240 Operators and Program Manual for a complete description of your program options 1 Choose Misc from the Edit ECR Data menu Then from the cascading menu choose Tare Weights The appropriate Tare Weight Programming dialog box displays 2 Enter a weight up to 9 999 lbs for each tare 3 Click Exit to save changes and return to the main...

Page 35: ...ions 1 Choose Misc from the Edit ECR Data menu Then from the cascading menu choose COM Port 1 Option The appropriate Serial Port Programming dialog box displays 2 Fill the applicable fields for the device you are using Be sure to select the appropriate scale printer or pole display type if necessary Edit fields with drop down list boxes by opening the list box and selecting from the available opti...

Page 36: ... bar at the bottom and right to view all of the key positions Yellow locations are fixed and cannot be changed The current function for each programmable location is displayed To change a programmable location open the Function Keys drop down list box and find the new function you wish to assign Then double click on the position where you wish the function assigned Programming Macros 1 Each Macro ...

Page 37: ...ators and Program Manual or the Samsung ER 5200 5240 Operators and Program Manual for a complete description of your program options 1 Choose Misc from the Edit ECR Data menu Then from the cascading menu choose Misc The appropriate Misc Programming dialog box displays 2 Double click on the option you wish to edit and then enter a new value 3 Click Exit to save changes and return to the main menu ...

Page 38: ...program options 1 Choose Misc from the Edit ECR Data menu Then from the cascading menu choose Macros from the Edit ECR Data menu The appropriate Macro Programming dialog box displays 2 Use the scroll bar at the right to view all of the key strokes for each macro use the scroll bar at the bottom to view all of the 10 macros 3 Edit or create a new macro string by opening the appropriate drop down li...

Page 39: ...ations from the Main menu to initiate communications with a Samsung ER 5200 series ECR Polling 1 Choose Polling from the Communications menu to connect to the store to poll reports The SAM52 Polling dialog box will display Note Polling setup file must be completed first ...

Page 40: ...t the Poll All Stores checkbox to poll all stores If not selected enter an individual store to poll in the Listbox of Stores field Listbox of Stores O Select an individual store to poll if the Poll All Stores check box is not selected Timer O Enter the military time the polling session is to begin if unattended polling is to be done Session R Select the polling session 0 2 Polling will proceed in ...

Page 41: ...x select the program components you wish to send to the ECR Click Check All to select all components A check mark means the item is selected 3 Click the Download button to initiate the download to the ECR click Exit to exit the window The Status field will monitor the progress of the download for each program component Passed will display in green when the program is successfully downloaded Fail w...

Page 42: ...be overwritten by the new data 2 From the Upload dialog box select the program components you wish to send to the ECR Click Check All to select all components A check mark means the item is selected 3 Click the Upload button to initiate the download to the ECR click Exit to exit the window The Status field will monitor the progress of the upload for each program component Passed will display in gr...

Page 43: ...en when polling is initiated 2 Click the Session 1 or Session 2 tabs to display the reports for the session 3 At the heading of each column view the type of report i e X1 Z1 etc Then indicate by selecting the check boxes in the column for the specific reports of that type you wish to take 4 Click Exit to save changes and return to the main menu ...

Page 44: ...m you must resize your image a Click OK to exit the Attributes dialog b Select your image Choose Select All from the Edit menu c Using the handles of the selected image resize the image Keep the image in the upper left corner of the screen d Choose Attributes from the Image menu The Attributes dialog box displays again Enter 384 in the Width field enter 192 in the Height field select Pixels as the...

Page 45: ...g box displays 2 Select the folder where the bitmap file you wish to use is located Select the Pre Logo bitmap file on the left and select the Post Logo bitmap on the right 3 Select the Download This File Pre Logo and or Download This File Post Logo checkboxes 4 Click the Download button When the logo loads successfully the download completed message displays after a short delay ...

Page 46: ...tion 29 Add the value of 1 to address 29 if you wish to print the pre graphic logo on the guest check Add the value of 2 to address 29 if you wish to print the post graphic logo on the guest check Option 30 Add the value of 1 to address 30 if you wish to print your custom bitmap instead of the default bitmap Thank You Your Receipt Add the value of 2 to address 30 if you wish to print your custom b...

Page 47: ...44 Menu Functions SAM52 User s Manual Print Choose Print from the Main menu to access the printing utilities described below ...

Page 48: ... report type from the drop down list box If no report type is selected SAM52 will display all reports for the specified date and key lock mode Keylock Mode O Select the mode of the report If no key lock mode is selected SAM52 will display all reports for the specified date and report type Grid Lines O Click the Grid Lines button to print display the selected report with or without grid lines White...

Page 49: ...ven day Uploads 1 Choose Log Files from the Print menu then choose Uploads to view and or print the uploads of a given day The Upload Log File Report dialog box for the selected store displays 2 Type or select a date from the File Date list box 3 Click the Load Table button to load the table for the selected file date 4 Click the Print Table button to print the table ...

Page 50: ...nloads to view and or print the uploads of a given day The Download Log File Report dialog box for the selected store displays 2 Type or select a date from the File Date list box 3 Click the Load Table button to load the table for the selected file date 4 Click the Print Table button to print the table ...

Page 51: ...olling activity of a given day The Download Log File Report dialog box for the selected store displays 2 Select the polling date from the drop down list box 3 Click the Load Table button to view the selected file date log 4 With the report in view click the Print Table button to print the report 5 Click Exit to return to the main menu ...

Page 52: ... print out the PLU file of the working store The PLU File dialog box displays 2 Click the Sort by PLU button to view the file sorted by PLU click the Sort by Descriptor button to view the file sorted by descriptor 3 Click the Print File button to print the file 4 Click Exit to return to the main menu ...

Page 53: ...ay and print out a specific range of the PLU file of the working store The PLU File dialog box displays 2 Enter or select the From PLU and To PLU numbers 3 Click the Load Grid button to view the selected PLUs 4 Click the Print File button to print the file 5 Click Exit to return to the main menu ...

Page 54: ... list for the reports you wish to consolidate 3 Chose the Report Type Financial PLU or Groups from the drop down list for your consolidated report 4 Click on Load Table to load the consolidated store report 5 Click on the Grid Lines icon to toggle between displaying grid lines on the table and not 6 Click on the White Gray icon to toggle between showing the descriptors in white or gray 7 Click on ...

Page 55: ...ll files deleted The message FINISHED will display when completed 3 Click Exit to return to the main menu Log Files Upload Download Poll 1 Choose Log Files Upload Download Poll from the Remove menu to delete unwanted poll log files The Remove Old Log Files dialog box will display 2 Enter the date through which you want old log files deleted The message FINISHED will display when completed 3 Click ...

Page 56: ...al attributes of an existing store 1 Choose Copy a Store from the Utilities menu 2 Select the store that you wish to copy from by clicking the Default Store field drop down list box 3 Enter the name of the store you wish to create in the New Copy Store field 4 Click the Copy button to create a new store with identical attributes as the default store 5 Click the Exit Copy button to return to the ma...

Page 57: ...2 Select the store that you wish to copy the PLU file from by clicking the Default Store field drop down list box 3 Select the name of the store you wish the PLU file copied to in the Copy PLU File to this Store field or click the Copy To All Stores check box 4 Click the Copy button to copy the PLU file to the selected store or all stores 5 Click the Exit button to return to the main menu ...

Page 58: ...3 Select Your Internet Connection from the drop down list All connections set up in your PC should display for you to chose from 4 Type in your Outgoing Mail Host Name SMTP in the appropriate location If you have trouble locating the host name please contact your e mail provider The host names vary greatly depending on the provider 5 Type in your E mail Account Logon Name 6 Type in your E mail Acc...

Page 59: ...ose when polling is completed 1 Choose Set Autopoll from the Utilities menu The Set to Automatically Poll dialog box displays 2 Select the first check box if you wish to automatically poll when SAM52 is executed Select the second check box if you wish to close SAM52 automatically when polling is completed 3 Click Exit 4 Close SAM52 and then restart it for changes to take effect ...

Page 60: ... You can set a time period that SAM52 will wait to successfully poll each report Leave this value at 0 unless you encounter difficulty polling Backup Poll Data Files Use this utility to backup polled data files to another disk drive Follow the screen instructons ...

Page 61: ...isplay to choose the default color Click on one of the color samples and click on OK to set the color selected as default 5 Select a key position or group of key positions and click on the Set Cell Text Font Color to Default Color icon to set the cell s text to the color selected as default 6 Select a key position or group of key positions and click on the Set Cell Background to Default Color icon...

Page 62: ...y to choose the default color Click on one of the color samples and click on OK to set the color selected as default 5 Select a key position or group of key positions and click on the Set Cell Text Font Color to Default Color icon to set the cell s text to the color selected as default 6 Select a key position or group of key positions and click on the Set Cell Background to Default Color icon to s...

Page 63: ...60 Menu Functions SAM52 User s Manual Quit Choose Quit from the Main menu to exit SAM52 For Windows ...

Page 64: ...rectory under the directory SAM52 for the store If you create a store named BIGBOYS the following will be created 1 A directory named SAM52 STORES BIGBOYS This directory holds all the programming files for this store 2 A directory named SAM52 STORES BIGBOYS POLL This directory holds all the daily polling files for this store ...

Page 65: ...acro msc misc mm mix and match pol in polling folder polled reports file tpl in polling folder temporary polling file Sam52 PLU File Structure Storename PLU FIELD START LENGTH STATUS 1 1 A C D PLU 2 4 DESCRIPTION 6 12 GROUP1 18 2 GROUP2 20 2 GROUP3 22 2 NEGATIVE ITEM 24 1 FOOD STAMP 25 1 TAX4 26 1 TAX3 27 1 TAX2 28 1 TAX1 29 1 OVERRIDE PRESET 30 1 PRESET 31 1 AUTO SCALE 32 1 SCALABLE 33 1 DISABLE ...

Page 66: ...RECEIPT 42 1 PRINT ON CHECK 43 1 PRINT ON DISPLAY 44 1 PRINT ON RECEIPT 45 1 COMP CONDIMENT 46 1 CONDIMENT 47 1 Not Used 48 1 Not Used 49 1 Not Used 50 1 Not Used 51 1 Not Used 52 1 PRINT ON JOURNAL 53 1 PRESET OVER MGT 54 1 RESET COUNTER 55 1 AUTO TARE 1 5 56 1 LINK PLU 57 4 PRICE 61 7 STOCK 68 6 MIX MATCH 74 2 COST 76 7 CR LF 83 2 TOTAL REC LENGTH 84 ...

Page 67: ...a forward slash and the time in hours minutes and seconds The last line of the entire session will be saved as END SESSION The last three characters of the line is ASCII character decimal 17 a left arrow This designates that this is the end of the polling session If you do not define any elements in your polling session you would have a polled file that would look something like this BIGBOYS 09 23...

Page 68: ... clerk from another See the example that follows Let s say our session consisted of the two elements X1 PLU and X1 Groups Your file SAM52 STORES BIGBOYS POLL 03172003 POL should look like this BIGBOYS 03 17 2003 14 26 45 X1 PLU PLU Count Amount PLU1 0001 1 00 1 00 PLU2 0002 1 00 1 00 PLU3 0003 1 00 1 00 PLU4 0004 1 00 1 00 PLU5 0005 1 00 1 00 PLU6 0006 0 00 0 00 PLU7 0007 0 00 0 00 Totals 5 00 5 0...

Page 69: ... 0 00 XMPT4 SALES 0 0 00 EATIN TTL 2 2 00 TAKEOUT TTL 0 0 00 DRTHRU TTL 0 0 00 1 0 0 00 2 0 0 00 3 0 0 00 4 0 0 00 5 0 0 00 NET SALE 20 280 15 CREDIT TAX1 0 0 00 CREDIT TAX2 0 0 00 CREDIT TAX3 0 0 00 CREDIT TAX4 0 0 00 FD S CREDIT 0 0 00 RETURN 2 6 00 ERROR CORR 0 0 00 PREVIOUS VD 1 1 00 VOID MODE 0 0 00 CANCEL 2 10 00 GROSS SALES 0 286 15 CASH SALES 14 56 95 CHECK SALES 1 200 00 R A 1 1 29 99 R A...

Page 70: ...0 00 SERVICE 0 0 00 MIX MATCH 0 0 00 PAYMENT TTL 0 0 00 OPEN CHK TTL 0 0 00 GRAND TOTAL 0 286 15 End Report Time Report X1 TIME Hour Count Amount 00 00 00 59 0 0 00 01 00 01 59 0 0 00 02 00 02 59 0 0 00 03 00 03 59 0 0 00 04 00 04 59 0 0 00 05 00 05 59 0 0 00 06 00 06 59 0 0 00 07 00 07 59 0 0 00 08 00 08 59 0 0 00 09 00 09 59 0 0 00 10 00 10 59 9 222 20 11 00 11 59 9 57 95 12 00 12 59 0 0 00 13 0...

Page 71: ...LU24 0024 0 00 0 00 PLU25 0025 0 00 0 00 PLU26 0026 2 00 6 00 PLU27 0027 0 00 0 00 LARGE PIZZA 0028 0 00 0 00 PEPPERONI 0029 0 00 0 00 MUSHROOM 0030 0 00 0 00 End Report Clerk Report Data for One Clerk Only X1 CLERK Clerk 1 CLERK 1 Count Amount NET SALE 20 280 15 NONTAX 37 259 19 TAX1 SALES 0 20 96 TAX2 SALES 0 0 00 TAX3 SALES 0 0 00 TAX4 SALES 0 0 00 TAX1 0 0 00 TAX2 0 0 00 TAX3 0 0 00 TAX4 0 0 0...

Page 72: ...DRWR TTL 22 305 14 PROMO 0 0 00 WASTE 0 0 00 TIP 0 0 00 TRAIN TTL 0 0 00 BAL FORWARD 0 0 00 GUESTS 0 0 00 P BAL 0 0 00 CHECKS PAID 0 0 00 SERVICE 0 0 00 NOSALE 1 0 MIX MATCH 0 0 PAYMENT TTL 0 0 Group Report X1 GROUPS Group Count Amount GROUP 1 47 00 280 15 GROUP 2 0 00 0 00 GROUP 3 0 00 0 00 GROUP 4 0 00 0 00 GROUP 5 0 00 0 00 GROUP 6 0 00 0 00 GROUP 7 0 00 0 00 GROUP 8 0 00 0 00 GROUP 9 0 00 0 00...

Page 73: ...00 BAUD NO PARITY 8 DATA BITS 1 STOP BIT and that SAM52 is set the same SAM52 Software Create a new store by selecting Create New from the Stores menu See Creating a New Store on page 10 Set the correct Communication Port and BAUD rate Be sure that the BAUD rate is identical to that set in the register port Only enter a phone number here if you are using a modem to poll data If your PC is using an...

Page 74: ...XD3 DTR4 GND5 DSR6 RTS7 CTS8 VCC9 1DCD 2RXD 3TXD 4DTR 5GND 6DSR 7RTS 8CTS 9RI Part 522038 Samsung DB 9M PC DB 25F DCD1 RXD2 TXD3 DTR4 GND5 DSR6 RTS7 CTS8 VCC9 1ChGND 2TXD 3RXD 4RTS 5CTS 6DSR 7GND 8DCD 20DTR Modem Connection Part 522034 Samsung DB 9M MODEM DB 25M DCD1 RXD2 TXD3 DTR4 GND5 DSR6 RTS7 CTS8 VCC9 1ChGND 2TXD 3RXD 4RTS 5CTS 6DSR 7GND 8DCD 20DTR PC Modem DB 25M DCD RXD TXD DTR GND DSR RTS ...

Reviews: