25
Alignment and Adjustments
4-4) Restoration Function for Power Outage
4-5) Set Point Shift Function
※
The FREEZER FAN and CONDENSER FAN are operated to High/Low rpm automatically according to the
operational condition.
※
⑤⑥
and
�
only explain the system operation state according to the ambient condition
1) When the freezer temperature is lower than 5
℃
, all functions on the display panel will be restored.
2) When the freezer temperature is higher than 5
℃
, all functions will be initialized.
(-20
℃
for the freezer, 3
℃
for the refrigerator, and Water for the Ice Type)
●
Press Freezer Temp. and Vacation buttons simultaneously for 12 seconds to get into this mode.
●
In this mode, only the display LEDs for temperature will be ON.
NO
Contents
REFRIGERATOR FAN High
REFRIGERATOR FAN Low
REFRIGERATOR DEFROST heater
Start mode
Overload mode
Low-temperature mode
Exhibition mode
COMPRESSOR
FREEZER FAN High
FREEZER FAN Low
FREEZER DEFROST Heater
CONDENSER FAN High
CONDENSER FAN Low
Dispenser-Heater
Water Tank Heater
Damper
Normal condition
�
Table of Load Mode Check List
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
�
�
4-3) Load Operation Check Function
1) In the normal operation, press Power Freeze and Vacation buttons simultaneously for 6 second, then the display panel
will blink for 2 seconds.
2) Press Fridge Temp. button
ⓐ
to get into this check mode with an audible tone.
3) Each illuminating LED segment stands for the component which has an ouput signal from the control board.
4) This mode will terminate automatically after 30 seconds.