49
Appendix
Ⅰ
Ⅰ
(Reference for circuit diagnostics)
Ref. 3) Check a load
Load
Measuremenr Termina l
Value
Contents
Cover Over Solenoid
Ice Solenoid Valve
Auger Motor
Cube Solenoid Valve
1) Beverage Station
TM
heater
2) Dispenser heater
3) Water tank heater
Ref. Def heater
Freezer Def heater
between CN70 13
and CN70 7
between CN70
9 and CN70 7
between CN70
11 and CN70 1
between CN71
7 and CN70 11
between CN71
5 and CN70 11
between CN71
3 and CN70 11
between CN71
1 and CN70 11
0
Ω
∞Ω
0
Ω
∞Ω
0
Ω
∞Ω
0
Ω
∞Ω
0
Ω
∞Ω
0
Ω
∞Ω
0
Ω
∞Ω
Temperature fuse, heater, wires short trouble
Temperature fuse, heater, wires disconnection trouble
Temperature fuse, heater, wires short trouble
Temperature fuse, heater, wires disconnection trouble
Heater, wires short trouble
Heater, wires, and connector disconnection
Coil, wires short trouble
Coil, wires disconnection trouble
Coil, wires short trouble
Coil, wires disconnection trouble
Coil, wires short trouble
Coil, wires disconnection trouble
Coil, wires short trouble
Coil, wires disconnection trouble
F-DEFROST HEATER
Unplug the powercord and disconnect the
main PCB CN70 and CN71, the measure the
follows :
1. As shown in table below, measure the
resistance between terminals, check load
trouble and wire connection error.
2. The diagram of circuit was drawn based on the
maximum load. When a repair is needed, see
the electric wiring diagram on the back of
refrigerator to troubleshoot the corresponding
model.
3. For safety, you must turn the power off.