Error Items

LED

TROUBLE

TESTING

I/M-SENSOR (R on Twin 
I/M units) 

Ice Maker Sensor Error- open or short-circuit, connector failure. Cause is 
also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

R-SENSOR 

Refrigerator Room Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F.

The voltage at MAIN PCB  
Sensor between 4.5V~1.0V

DEFROST SENSOR OF 
R ROOM 

Ref. Defrost Sensor Error- open or short-circuit, connector failure. Cause is 
also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

R-FAN ERROR 

This error indicates the Refrigerator Evap Fan is not spinning at the correct 
RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  shall 
be between 7V~12V

I/M FUNCTION 
ERROR(R on Twin I/M)  

This error indicates the Ice tray has not returned to level after an ice 
harvest. The error is displayed after three failed attempts.

Replace I/M

COOL SELECT ZONE 
SENSOR

Cool Select Zone Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB  
Sensor between 4.5V~1.0V

R-DEFROSTING 
ERROR 

Refrigerator Room defrost heater- open or short-circuit, connector failure, 
or defective temperature fuse/bi-metal.  Defrost on over 80 minutes

Disconnect defrost connector 
from PCB,  check resistance

PANTRY-DAMPER-
HEATER ERROR 

Sensor system in Pantry Room errors

Disconnect heater connector 
from PCB,  check resistance

 CR-SENSOR  4-Door 

CR Room Sensor Error- This can be an open or short-circuit, contact 
failure. Cause is also a temperature reading > 122°or < -58 ° F.

The voltage of MAIN PCB 
Sensor between 4.5V~1.0V

DEFROST SENSOR CR  
ROOM 4-Door

CR Room Defrost Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F.

The voltage at MAIN PCB  
Sensor between 4.5V~1.0V

DEFROST SENSOR OF 
CF ROOM 4-Door

CF Room Defrost Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F.

The voltage at MAIN PCB  
Sensor between 4.5V~1.0V

CR-DEFROSTING 
ERROR 4-Door

CR Compartment Defrosting heater- open or short-circuit, connector 
failure, or defective temperature fuse/bi-metal.  Defrost on for over 80 
minutes

Disconnect heater connector 
from PCB,  check resistance

CF-DEFROSTING 
ERROR 4-Door

CF Compartment defrosting heater-open or short-circuit, connector failure, 
or defective temperature fuse/bi-metal.  Defrost on for over 80 minutes

Disconnect heater connector 
from PCB,  check resistance

WATER TANK HEATER 
ERROR 

Error is displayed when the water reservoir tank heater is open or shorted 

Disconnect heater connector 
from PCB,  check resistance

EXT-SENSOR 

Ambient Temp. Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-SENSOR 

Freezer Compartment Sensor Error- open or short-circuit, connector 
failure. Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-DEF-SENSOR 

Freezer Room Defrost Sensor Error- open or short-circuit, connector 
failure. Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-FAN ERROR 

This error indicates the Freezer Evap. Fan is not spinning at the correct 
RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  shall 
be between 7V~12V

C-FAN ERROR 

This error indicates the Condenser Fan is not spinning at the correct RPM 
or the fan feedback line is open.

Fan voltage at MAIN PCB  shall 
be between 7V~12V

CF-SENSOR 4-Door

CF Room Sensor Error- open or short-circuit, connector failure. Cause is 
also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-DEFROSTING 
ERROR 

Freezer defrosting heater- open or short-circuit, connector failure, or 
defective temperature fuse/bi-metal.  Defrost on for over 80 minutes

Disconnect defrost connector 
from PCB,  check resistance

CF-FAN ERROR              
4-Door

This error indicates the CF Compartment Evap. Fan is not spinning at the 
correct RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  shall 
be between 7V~12V

CR-FAN ERROR              
4-Door 

This error indicates the CR Compartment Evap. Fan is not spinning at the 
correct RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  shall 
be between 7V~12V

ICE PIPE HEATER 
ERROR 

Error is displayed when the ice maker fill pipe heater is open or shorted. 

Replace Fill Tube Ass'y

Uart ERROR 
COMMUNICATION 

This error is not applicable, if the error is detected during diagnostic testing 
please ignore it.

No Repair Necessary

L?M ERROR 
COMMUNICATION 

Communication error within the Main PCB 

Replace main PCB

P?M ERROR 
COMMUNICATION 

Communication between the Main PCB and Keypad 

Check wiring in door & cabinet, 
Panel PCB, Main PCB

                                    Samsung 'Refrigerator' Diagnostic Code Quick Guide

3

Summary of Contents for RM255 series

Page 1: ... Heater 2880Ω 5 120vac Water Tank Heater 29Ω 5 12vdc Fill Tube Heater 29Ω 5 12vdc Sensors 2 5kΩ 89kΩ N A 1 4 5vdc Fans N A N A 7 12vdc 1 Compressor Sub condenser Hot Pipe Back Clus ter Pipe Dryer R Capillary Tube Refrigerator Evapo rator CR Evaporator Connected Capillary Freezer Evaporator CF Evaporator Suction Pipe Compressor 2 Compressor Sub condenser Hot Pipe Back Clus ter Pipe Dryer F Capillar...

Page 2: ...ice then defrost and check the motor again after removing power from the unit If the evaporator is ice blocked and thus blocking the air flow the fan will over RPM and it is stopped Remove ice and check the motor again If everything is clear around the fan blade then the motor would be at fault Continuous fan errors will be displayed on the front panel display PLEASE NOTE The door switches control...

Page 3: ...or CF Compartment defrosting heater open or short circuit connector failure or defective temperature fuse bi metal Defrost on for over 80 minutes Disconnect heater connector from PCB check resistance WATER TANK HEATER ERROR Error is displayed when the water reservoir tank heater is open or shorted Disconnect heater connector from PCB check resistance EXT SENSOR Ambient Temp Sensor Error open or sh...

Page 4: ...sw 6 vdc GND CN76 1 11 12 VDC Blk S Blu 1 2 CF Fan Mtr Blk Brn 7 1 3 CF Fan FG Red 1 4 Ice Pipe Heater Blk Org 11 5 CR Fan Mtr S Blu Yel 6 CR Fan FG Pnk 11 10 H2O Tank Htr S Blu W CN73 120vac 1 CN70 9 Cube Mtr Yel Red 3 CN70 9 Auger Mtr Pnk Red 5 CN70 9 Water Solenoid Valve W Blk Red 7 CN70 9 Ice Solenoid Valve Prp Red CN72 120vac 1 CN70 9 CR Room Lt Wht Red 3 CN70 9 CF Room Lt Brn Red 5 CN70 9 R ...

Page 5: ...Ice Maker Water Filter Water Tank SMPS Main PCB Push up sharply to loosen Swing bezel away from RM255 ...

Page 6: ...Service Access Disassembly of Quatro Cool Evaporator Covers both access the same way ...

Page 7: ...Accessing the Refrigerator Evaporators Pull cover up and out far enough Water Tank Heater Connector Fresh Food Convertible Section Failure of the Drain Hose Hea could cause water build up o ...

Page 8: ...Remove 4 screws Snap off caps Accessing Freezer Evaporator Snap off cover Unplug wire ha Failure of the Defrost Drain Hose Heater could cause ice build up on freezer floor and cooling issues in Freezer ...

Page 9: ...RM255 9 ...

Reviews: