65
5. SELF DIAGNOSIS & TROUBLE SHOOTING
4-1-3-6) Option Setting Function
●
There is no extra option setting function and it can be controlled with DIODE (1N4148).
1) Freezer Temp Shift
DIODE 1N4148 (
●
Yes ,
❍
No)
D603
❍
❍
❍
❍
●
●
●
●
D602
❍
❍
●
●
❍
❍
●
●
D601
●
❍
●
❍
●
❍
●
0.0 ºC
-0.5 ºC
-0.1 ºC
-1.5 ºC
+0.5 ºC
+1.0 ºC
+1.5 ºC
+2.0 ºC
DIODE (1N4148)
Temperature
Compensation
2) Fridge Temp Shift
DIODE 1N4148 (
●
Yes ,
❍
No)
D607
❍
❍
❍
❍
●
●
●
●
D606
❍
❍
●
●
❍
❍
●
●
D605
●
❍
●
❍
●
❍
●
0.0 ºC
-0.5 ºC
-0.1 ºC
-1.5 ºC
+0.5 ºC
+1.0 ºC
+1.5 ºC
+2.0 ºC
DIODE (1N4148)
Temperature
Compensation
3) Defrost Termination Temp
DIODE 1N4148 (
●
Yes ,
❍
No)
D614
❍
❍
●
●
D613
●
❍
●
12 ºC
10 ºC
15 ºC
17 ºC
DIODE (1N4148)
Temperature
Compensation