SERVICE BULLETIN 
PRODUCT: Refrigerator 
BULLETIN NUMBER: 
ASC20100714001 
DATE: 
07/14/2010 

Please review before ordering 
any parts. 

CN78 

  

                                                              

1-3 Fz LED (Blk-Gry)     

                                                            

4-7-FF LED (Red-Gry)

 

CN71 All 120vac                                                     

5-N (Gry) 

                                                                         

9-Def Htr Common (Org)

                                                                      

Summary of Contents for RFG298AA**/XAA

Page 1: ...Saver Fridge simul taneously No sound when both buttons are pressed at the same time til it beeps and goes blank 8 12 seconds Publication tsRFG298AA Revision Date 03 30 2011 Component Value Chart Press Freezer button a second time to Force Mid Speed Run 3600RPM 2450RPM 2200RPM NOTICE Parts Change The interior lighting changed from incandescent lighting to LED lighting The new parts are NOT interch...

Page 2: ...ivity for 5 cycles 10 seconds off 3 seconds on the fan drive circuit is disabled for 10 minutes TO TEST THE FAN CIRCUIT VOLTAGE Power off and back on to check the DC voltage to the motor wait from 10 to 60 seconds for the fan voltage to kick in and then check fan voltage the average reading is 9 VDC If you get 3 seconds of voltage every 10 seconds for the 5 fan power up cycles then the Main PCB is...

Page 3: ... Sensor will check the temperature when it is lower than 1 5 for more than 5 minutes it will do a harvest with or without ice in the tray then fill with water 58 minutes after water is supplied to the Ice Tray the Ice Maker Sensor temperature will be checked When the Ice Maker Sensor maintains lower than 1 5 for 5 minutes it completes the harvest if the ice bin is not sensed as full Thermistor sen...

Page 4: ...e error is displayed after three failed attempts Replace I M WATER HEATER ERROR Error is displayed w hen the w ater reservoir tank heater is open or shorted Disconnect heater connector from PCB check resistance EXT SENSOR Ambient Temp Sensor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor betw een 4 5V 1 0V F SENSOR Freez...

Page 5: ...30 2011 5 SERVICE BULLETIN PRODUCT Refrigerator BULLETIN NUMBER ASC20100714001 DATE 07 14 2010 Please review before ordering any parts CN78 1 3 Fz LED Blk Gry 4 7 FF LED Red Gry CN71 All 120vac 5 N Gry 9 Def Htr Common Org ...

Page 6: ...2 Red Blk 5vdc CN75 To Comp Inverter Board 1 CN76 1 Blk Gry 13vdc 2 CN76 1 Brn Gry 5vdc 4 3 Compressor control Org Red 2 2 8vdc CN79 2 7 Fill tube heater freezer Blu Wht 13vdc 3 7 Water Tank Htr Pnk Wht 13vdc CN30 Sensors Switches 1 5 Freezer Dr Sw Blk Gry 5vdc 1 5 Freezer Dr Sw Blk Gry 5vdc 2 CN50 7 R Door Sw Prp Gry 5vdc 3 CN76 1 F Sensor Red Gry 3 5 4 2vdc 4 CN76 1 F Def Sensor Org Gry 2 3 4 2v...

Page 7: ... tsRFG298AA RevC 03 30 2011 7 Late Production change ...

Page 8: ...nd check resistance to the windings Aproxametly10 ohms If not correct inspect wire harness if OK replace compressor 5 Disconnect CN02 SMPS PCB check resistance to Overload if open replace overload CN04 Compressor Control 2 CN40 4 5vdc Brn Gry 4 Comp Signal Org CN03 Compressor Windings 1 Compressor Blue 3 Compressor Prp 5 Compressor Wht CN02 Overload A C Line 1 OLP Brn 3 OLP S Blu 3 L Blk 1 N Red C...