81
TROUBLESHOOTING
4-2-3. If ICE Room Fan does not operate
- This refrigerator has BLDC FAN motor. BLDC motor is driven by DC7~12V.
- When COMP ON, normally operates with F-FAN motor.
- If there is any trouble, you should select the self-diagnostic function to check the trouble before power off.
Start
Execute manual operation
No
Yes
Yes
No
Yes
Yes
No
No
Is COMPRESSOR ON ?
Is the Ice Room
temperature suitable for
the Fan working?
◆
Predicted Cause
①
FAN-MOTOR troubles itself
②
Bad wiring connections.
③
Wrong Input of the fan motor rotation pulse
Reference
CN76 #6 will generate the pulse signal when motor rotates.
These signals will be input into MICOM.
Unless signals are not input during motor operating, will be ON
10seconds after fan OFF. But if signals are not still taken, the
above operation will be retried four times more. If signals are not
taken continuously, the motor will be restarted after 10 minutes.
This function is against the case that motor movement would be
restrained by foreign matters like ice.
- When pressing the ICE TEST S/W for a certain period of time
(over 1.5sec), the function is accomplished. After beginning of
TEST mode, Ice maker heater turns on for initial 2 minutes, if the
ice making temperature is below 0
℃
.
- If it exceeds 0
℃
, Ice maker heater turns on for initial 30 seconds.
- After Ice maker heater turns on for 30 seconds, it turns off and
then Ice maker motor turns on.
- As the Ice maker motor turns on, TEST MODE COUNT operates.
(6 minutes count)
Condition
- Ambient temperature : 32
℃
/75%
- Notch : 2
℉
/38
℉
(-19.0
℃
/3.3
℃
)
Initial full of ice bucket capacity : 794 g, 58ea
Is the voltage between
MAIN PCB REG1 Heater Sink and
CN76-”2” (Black) around
DC7~12V?
Does DC7~12V alternate
with below DC2V between MAIN PCB REG1
Heater Sink and CN76-”2”(Black)?
FAN works normally
Operation
temperature/ready
Replace MAIN PCB
FAN pulse voltage
CN76-”6”(Pink)
Typical PCB Ground
REG1 Heater Sink
Ice Room control temperature
Ice ON
8.6
℉
(-13
℃
)
Ice OFF
26.6
℉
(-3
℃
)
The voltage is variable due to pulse
signal but measured about 2~3V with the
Multi-Meter.
☞
Display for checking the self-diagnostic function
☞
Checking method of Ice Room FAN Motor Voltage with the voltage between typical PCB Ground
REG1 Heater Sink and Ice Room FAN ; CN7~12V(Black) shall be less than DC 6~12V.
- Additional check if resistance values are different after measurement.
Typical PCB Ground
REG1 Heater Sink
1) Ice Room - FAN
Ice Room FAN ERROR
AW3 SM-EN 2011.3.31 2:56 PM 페이지81 in
Summary of Contents for RF4287HABP
Page 86: ...87 TROUBLESHOOTING IPM FREEWHEELING DIODE VOLTAGE VALUE AW3SM EN2011 3 312 56PM페이지87 in ...
Page 96: ...97 TROUBLESHOOTING SPM Internal DIODE Voltage AW3SM EN2011 3 312 56PM페이지97 in ...
Page 98: ...99 TROUBLESHOOTING INVERTER PCB Circuit Diagram AW3SM EN2011 3 312 56PM페이지99 in ...
Page 124: ...125 7 1 Model RFG295AA BETTER 7 WIRING DIAGRAM BLU BLU AW3SM EN2011 3 312 57PM페이지125 in ...
Page 125: ...126 7 2 Model RF4287AA BEST 7 WIRING DIAGRAM AW3SM EN2011 3 312 57PM페이지126 in ...
Page 126: ...127 7 3 Model RFG299AA 7 LCD 7 WIRING DIAGRAM BLU BLU AW3SM EN2011 3 312 57PM페이지127 in ...
Page 127: ...128 7 4 Model RFG294AA SEARS 7 WIRING DIAGRAM AW3SM EN2011 3 312 57PM페이지128 in ...
Page 129: ...130 8 SCHEMATIC DIAGRAM 8 1 2 INVERTER BLOCK RF4287 AW3SM EN2011 3 312 58PM페이지130 in ...
Page 130: ...131 8 2 CIRCUIT DIAGRAM SCHEMATIC DIAGRAM 8 2 1 MAIN AW3SM EN2011 3 312 58PM페이지131 in ...
Page 131: ...132 SCHEMATIC DIAGRAM 8 2 2 INVERTER AW3SM EN2011 3 312 58PM페이지132 in ...