English
11
01
SETTING
UP
With the door opened
1.
Remove the 3 screws holding down the TOP
TABLE (
1
) and separate the connected wires.
1
2.
Disconnect the two connectors (
2
) on the
left side door. To remove the water coupler
from the hinge, twist and pull it from the hinge.
Remove the water line (
3
) while pressing the
marked part (
4
) of the water line coupler.
2
3
4
3.
Pull and remove the hinge lever (
5
). Remove
the ground screw (
6
)
attached to the upper
left door hinges with a philips screwdriver (+).
Remove the upper left and right door hinges
(
7
).
5
6
7
4.
Lift the door straight up to remove.
5.
Remove the screw (
8
) attached to the
lower left and right door hinges with a philips
screwdriver (+). Remove the 2 hex head bolts
(
9
)
attached to the lower left and right door
hinges with an allen wrench (3/16”). Remove
the lower left and right door hinges (
10
).
Allen wrench
10
8
9
RF30KMED_DA68-02894B-02_EN.indd 11