Error Items

LED

TROUBLE

TESTING

I/M-SENSOR (R on 
Twin I/M units) 

Ice Maker Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

R-SENSOR 

Refrigerator Room Sensor Error- open or short-circuit, connector 
failure. Cause is also a temperature reading > 122°or < -58 ° F.

The voltage at MAIN PCB  
Sensor between 4.5V~1.0V

DEFROST SENSOR 
OF R ROOM 

Ref. Defrost Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

R-FAN ERROR 

This error indicates the Refrigerator Evap Fan is not spinning at the 
correct RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  
shall be between 7V~12V

I/M FUNCTION 
ERROR(R on Twin I/M)  

This error indicates the Ice tray has not returned to level after an ice 
harvest. The error is displayed after three failed attempts.

Replace I/M

R-DEFROSTING 
ERROR 

Refrigerator Room defrost heater- open or short-circuit, connector 
failure, or defective temperature fuse/bi-metal.  Defrost on over 80 
minutes

Disconnect defrost connector 
from PCB,  check resistance

PANTRY-DAMPER-
HEATER ERROR 

Sensor system in Pantry Room errors

Disconnect heater connector 
from PCB,  check resistance

PANTRY-SENSOR 
ERROR

CR Room Sensor Error- This can be an open or short-circuit, contact 
failure. Cause is also a temperature reading > 122°or < -58 ° F.

The voltage of MAIN PCB 
Sensor between 4.5V~1.0V

WATER HEATER 
ERROR 

Error is displayed when the water reservoir tank heater is open or 
shorted 

Disconnect heater connector 
from PCB,  check resistance

EXT-SENSOR 

Ambient Temp. Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-SENSOR 

Freezer Compartment Sensor Error- open or short-circuit, connector 
failure. Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-DEF-SENSOR 

Freezer Room Defrost Sensor Error- open or short-circuit, connector 
failure. Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-FAN ERROR 

This error indicates the Freezer Evap. Fan is not spinning at the 
correct RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  
shall be between 7V~12V

C-FAN ERROR 

This error indicates the Condenser Fan is not spinning at the correct 
RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  
shall be between 7V~12V

FRENCH DOOR ICE 
ROOM SENSOR 

Ice Room Sensor Error- open or short-circuit, connector failure. 
Cause is also a temperature reading > 122°or < -58 ° F

The voltage at MAIN PCB 
Sensor between 4.5V~1.0V

F-DEFROSTING 
ERROR 

Freezer defrosting heater- open or short-circuit, connector failure, or 
defective temperature fuse/bi-metal.  Defrost on for over 80 minutes

Disconnect defrost connector 
from PCB,  check resistance

FRENCH DOOR ICE 
ROOM FAN ERROR 

This error indicates the Ice Room Compartment Evap. Fan is not 
spinning at the correct RPM or the fan feedback line is open.

Fan voltage at MAIN PCB  
shall be between 7V~12V

Uart ERROR 
COMMUNICATION 

This error is not applicable, if the error is detected during diagnostic 
testing please ignore it.

No Repair Necessary

L

M ERROR 

COMMUNICATION 

Communication error within the Main PCB 

Replace main PCB

P

M ERROR 

COMMUNICATION 

Communication between the Main PCB and Keypad 

Check wiring in door & 
cabinet, Panel PCB, Main 
PCB

                                                                       Samsung 'Refrigerator' Diagnostic Code Quick Guide