43
TROUBLESHOOTING
2) If R Sensor has trouble
Bad contact of connector/Insert correctly
Is Main PCB
Connector CN30 inserted
correctly?
Is R Sensor unit
normal?
Is the voltage between Main
PCB Connector CN30- #3(Red) & REG1,
Heat Sink normal?
Is the input
voltage to IC10 MICOM #53
normal?
Start
NO
YES
YES
YES
YES
Replace the temperature sensor
NO
Recheck the wire connection part
NO (0.6V > Measurement < 4.6V)
Check the Cold solder joint,
short, solder Touch
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connector.
** Measuring point of resistance value according
to Sensor **
R : CN30 #3
↔
#8 Measure the resistance value
**
∞Ω
: Short trouble /
∞Ω
: Open trouble
Sensor MICOM/Connector number
Voltage is measured between 4.6V ~ 0.6V
Voltage of IC10 MICOM #53 is same with the
measuring voltage of CN30-#3(Red), REG1, & Heat
Sink from PCB common Ground part.
→
Check the measure on MICOM or Sensor
Marking #1(R301).
DATA1.
Temperature Table
ERROR Code
Refer to circuit diagram in the manual
R
Connector CN30#6(White) to REG1
HEAT-SINK PCB typical Ground
☞
Checking method of R Sensor resistance CN30-
#3(White)
↔
#8(Gray)
-. Compare with the temperature table after
measuring
☞
Checking method of R Sensor voltage.
-. Measure the voltage of Sensor Check Point #1(IC10 MICOM
#53) on PCB or CN30-#3(Red)
↔
REG1, Heat Sink
-. Compare with the temperature table after measuring. Below is
measuring voltage of CN30-#3(Red)
↔
REG1, Heat Sink.
Common PCB
Ground of REG1, Heat Sink
Summary of Contents for RF195AC
Page 16: ... AXIAL FLOW FAN AXIAL FLOW FAN 16 PRODUCT SPECIFICATIONS 2 8 Cooling Air Circulation ...
Page 84: ...84 EXPLODED VIEW PARTS LIST 5 3 Disassembly of Freezer Door 1 1 1 1 1 1 1 2 1 1 2 1 1 3 ...
Page 87: ...87 6 2 Connector Layout with part position Main Board PCB DIAGRAM ...
Page 88: ...88 7 Wiring Diagram ...
Page 89: ...89 8 1 Refrigerator Block Diagram 8 Schematic Diagram ...
Page 90: ...90 SchematicDiagram 8 2 Main ...