
36
Trouble shooting
•
Incorrect handling of thermostat, safety valve or other valves may lead to tank rupture. When servicing the unit
follow instructions carefully:
•
Always turn off main power supply when water supply is being shut off.
•
Test the free operation of the safety valve regularly by opening the valve ensuring the water flows freely.
•
Electrical connection and all servicing of the electrical components should only be carried out by an authorized
electrician.
•
Fitting and all servicing of plumbing fixtures should only be carried out by an authorized installer.
•
When replacing the thermostat, safety valve or any other valve or part supplied with this unit, use only approved
parts of the same specification.
WARNING
Error codes
If the unit has some problems and does not work normally, error code is shown on the OUTDOOR UNIT main PBA or LCD
of the wired remote controller.
Display
Explanation
Error Source
101
CONTROL KIT / OUTDOOR UNIT wire connection error
CONTROL KIT,
OUTDOOR UNIT
162
EEPROM Error
CONTROL KIT
201
CONTROL KIT/OUTDOOR UNIT communication error (Matching error)
CONTROL KIT,
OUTDOOR UNIT
202
CONTROL KIT/OUTDOOR UNIT communication error (3 min)
CONTROL KIT,
OUTDOOR UNIT
203
Communication error between INVERTER and MAIN MICOM (6 min)
OUTDOOR UNIT
221
OUTDOOR UNIT temperature sensor error
OUTDOOR UNIT
231
Condenser temperature sensor error
OUTDOOR UNIT
251
Discharge temperature sensor error
OUTDOOR UNIT
320
OLP sensor error
OUTDOOR UNIT
403
Detection of OUTDOOR UNIT compressor freezing (During cooling operation)
OUTDOOR UNIT
404
Protection of OUTDOOR UNIT when it is overload (during Safety Start, Normal
operation state)
OUTDOOR UNIT
416
Discharge of a compressor is overheated
OUTDOOR UNIT
419
OUTDOOR UNIT EEV operation error
OUTDOOR UNIT
425
Power source line missing error (only for 3-phase model)
OUTDOOR UNIT
440
Heating operation blocked (outdoor temperature over 35°C)
OUTDOOR UNIT
441
Cooling operation blocked (outdoor temperature under 9°C)
OUTDOOR UNIT
458
OUTDOOR UNIT fan1 error
OUTDOOR UNIT
461
[Inverter] Compressor startup error
OUTDOOR UNIT
462
[Inverter] Total current error/PFC over current error
OUTDOOR UNIT
463
OLP is overheated
OUTDOOR UNIT
EHS mono_RC***MHXGA_IM_E_34411A(3).indd 36
2012-11-26 오후 3:02:01