74
* Check after disassembling connected to MAIN PCB CN30&CN32
* Because it is NTC TYPE Sensor,risistance decreases as temp increases
1. Measure resistance between CN30
⑦
and
⑥
for R-Sensor.
2. Measure resistance between CN30
②
and
③
for F-Sensor.
3. Measure resistance between CN30
⑧
and
⑥
for R Defrost Sensor.
4. Measure resistance between CN30
⑥
and
④
for F Defrost Sensor.
5. Measure resistance between CN31
①
and
④
for Ambient Sensor.
6. Compare the above values with current temps of Sensor locations
(4-6.Temp Sensing Circuit Table)and Part Spec in Manual and evaluate them.
1
2
3
4
PBA MAIN
PBA PANEL
TRANS DC
SENSOR
05 W2 PBA MAIN
05 W2 PBA PANEL,BLUE
115V/60Hz
220V/50,60Hz
127V/60Hz
230V/60Hz
F DEFROST SENSOR
R DEFROST SENSOR
F SENSOR
R SENSOR
AMBIENT SENSOR
- The second part (DA41-XXXXX?)of CODE for MAIN PCB ASS'Y PART may change according to
MICOM or Option change,so check it when asking for parts.
DA41-00293A
DA41-00264A
DA26-00022B
DA26-00022C
DA26-00022D
DA26-00022E
DA32-00006C
DA32-00006C
DA32-10105S
DA32-10105T
DA32-00011L
NO
ITEM
SPEC
CODE NO
REMARK
15-3) Others (Measure Load Terminals)
15-2) Others (Measure Sensor Terminals)