Sensor Short : Micom 0V.
Sensor Open : Micom 5V.
※
Sensor partial pressure resistance 10K
Ω
* Voltage conversion table depends on H/W structure of MICOM port input voltage.
Temp.(
℉
℉
)
-43.6
-41.8
-40.0
-38.2
-36.4
-34.6
-32.8
-31.0
-29.2
-27.4
-25.6
-23.8
-22.0
-20.2
-18.4
-16.6
-14.8
-13.0
-11.2
-9.4
-7.6
-5.8
-4.0
-2.2
-0.4
1.4
3.2
5.0
6.8
8.6
10.4
Temp.(
℉
℉
)
12.2
14.0
15.8
17.6
19.4
21.2
23.0
24.8
26.6
28.4
30.2
32.0
33.8
35.6
37.4
39.2
41.0
42.8
44.6
46.4
48.2
50.0
51.8
53.6
55.4
57.2
59.0
60.8
62.6
64.4
66.2
Temp.(
℉
℉
)
68.0
69.8
71.6
73.4
75.2
77.0
78.8
80.6
82.4
84.2
86.0
87.8
89.6
91.4
93.2
95.0
96.8
98.6
100.4
102.2
104.0
105.8
107.6
109.4
111.2
113.0
114.8
116.6
118.4
120.2
Resistance(
Ω
Ω
)
98870
93700
88850
84150
79800
75670
71800
68150
64710
61480
58430
55550
52840
50230
47770
45450
43260
41190
39240
37390
35650
33990
32430
30920
29500
28140
26870
25650
24510
23420
22390
Resistance(
Ω
Ω
)
21410
20480
19580
18730
17920
17160
16430
15740
15080
14450
13860
13290
12740
12220
11720
11250
10800
10370
9959
9569
9195
8839
8494
8166
7852
7552
7266
6992
6731
6481
6242
Resistance(
Ω
Ω
)
6013
5792
5581
5379
5185
5000
4821
4650
4487
4329
4179
4033
3894
3760
3631
3508
3390
3276
3167
3062
2962
2864
2770
2680
2593
2510
2429
2352
2278
2206
Voltage(V)
4.541
4.518
4.494
4.469
4.443
4.416
4.389
4.360
4.331
4.301
4.269
4.237
4.204
4.170
4.134
4.098
4.061
4.023
3.985
3.945
3.905
3.863
3.822
3.778
3.734
3.689
3.644
3.597
3.551
3.504
3.456
Voltage(V)
3.408
3.360
3.310
3.260
3.209
3.159
3.108
3.057
3.006
2.955
2.904
2.853
2.801
2.750
2.698
2.647
2.596
2.545
2.495
2.445
2.395
2.3462
.296
2.248
2.199
2.151
2.104
2.057
2.012
1.966
1.922
Voltage(V)
1.878
1.834
1.791
1.749
1.707
1.667
1.626
1.587
1.549
1.511
1.474
1.437
1.401
1.366
1.332
1.298
1.266
1.234
1.203
1.172
1.143
1.113
1.085
1.057
1.030
1.003
0.977
0.952
0.928
0.904
Ref. 7) Table of temperature sensor according to resistance and voltage conversion.
Summary of Contents for RB1955SWRB1955SH
Page 7: ...5 WARRANTY INFORMATION 7 ...
Page 11: ...11 Refrigeration Cycle and Cool Air Circulation Route 7 2 Cool Air Circulation ...
Page 33: ...33 Circuit Descriptions ...
Page 37: ...37 Diagnostics 5 If the defrost sensor of the freezer has trouble ...
Page 40: ...40 Diagnostics 11 5 If the refrigerator fan doesn t work ...
Page 41: ...41 Diagnostics 11 6 If the compressor cooling fan motor doesn t work ...
Page 43: ...43 Diagnostics ...
Page 45: ...45 Diagnostics 2 If beep sounds continuously 3 When the digital panel PCB does not light ...
Page 46: ...46 Diagnostics 4 When a button of the digital panel is not selected ...
Page 48: ...48 12 Illustrated Parts Catalog 12 1 Freezer ...
Page 50: ...50 Illustrated Parts Catalog 12 2 Refrigerator ...
Page 52: ...52 Illustrated Parts Catalog 12 3 Disassemblyof Door ...
Page 54: ...54 Illustrated Parts Catalog 12 4 Cabinet ...
Page 61: ...61 11 PCB Circuit Diagram ...