Remove the cap at the end of the white
water line and slide the
flexible tube (A)
to the white water line. Then, connect
the white water line to the bottom of
the
valve (B)
(with a blue water line).
NOTE
Dispose the cap immediately after
removing it from the water line. Do not
play with the cap or put it in your mouth.
A
NOTE
There is
line (A)
marked on the white water
line. Make sure to insert the water line up
to the marked line when you connect it to
the valve.
A
16.
Connect the
valve connector (A)
to the
port in the compressor compartment.
(See the figure for the location of the
port.) Make sure the connector is fully
inserted. (You should hear a clicking
sound.)
A
17.
Secure the
valve bracket (A)
to the
refrigerator as shown in the figure.