- 30/39 -
Step 1
IE Check
①
Check if Main PBA 1E Error occurs.
②
Water level sensor Check
- Measure the coil resistance to check for the
breakage.
☞ Maintain the coil resistance at 20~24Ω ->
If O.L, replace it.
③
Check the condition of contact between water
level sensor and terminal.
- The terminal is not completely inserted into
water level sensor, which is contact fail.
④
Voltage of Water Level Sensor
- Power on and separate wire connector
from water level sensor.
And then check Voltage value between
orange and violet wire of water level sensor.
☞ The Voltage value : 1.6v
- If the value is not normal, replace the PBA.
Step 2
OE / SUdS Check
①
Customer uses too much of normal detergent.
- It is filled with foam inside because the user uses
too much of normal detergent for Top-Load
washers.
- Explain the recommended amount of he-mark
detergent for front-load washers to be used.
②
If water is continuously supplied, due to water
supply valve leakage,
- Replace the water supply valve.
③ The top part of water level sensor shall not be
adjusted by applying Bond after the setup at the
time of factory shipment.
※ The Reset frequency changes during adjustment;
thus, spinning mode is not activated.
Check Point
Check the water level sensor and the connection.
Tip 4-3. IE / OE Abnormality
※ Not Adjust Bolt