OH85N-D(K)/(LH85OHNDKGB/**)
Single enclosure unit
Design the enclosure unit according to the following specifications to keep discharged hot air from flowing back into the
inlet.
•
Air inlet ( )
Open area of Enclosure Ventilation holes: 100,000
mm or more
Ventilation opening ratio (% of total opening): 70 % or more
•
Air outlet ( )
Open area of Enclosure Ventilation holes: 80,000
mm or more
Ventilation opening ratio (% of total opening): 70 % or more
–
Design the locations of the enclosure unit inlet and outlet to match the locations of the product inlet and outlet.
1 x N one-side unit design
–
Refer to the 'Total open area of the ventilation holes and ratio’. (Page 30)
Product 2
Product 1
Product 3
–
The guide for OH85N-D(K)/(LH85OHNDKGB/**) only applies when the product is used with an enclosure that has a
protective glass added to the front side.
English - 31