- 28 -
This document can not be used without Samsung’s authorization.
4-4 Electrical Malfunction
Troubleshooting (Power)
Check terminal block voltage.
(220V~240V, 50/60Hz)
YES
YES
YES
NO
No Power
Check the wiring.
NO
Check the votage of PCB, SMPS
-input : 220V~240V
-output : 12V, 5V
Replace the defected PCB.
Check the terminal block connections
Check the circuit breaker.
Replace or Repair the wiring
Troubleshooting (Heating)
Check the relay terminal voltage
(220V~240V)
NO
YES
YES
NO
Heating Failure
Check the wiring.
NO
Check the all IGBT terminal resistance
(G-E, G-C, E-C)
Is there any shorted circuit?
Perform the 'PCB failure' process
Repair the relay or missing circuit
component.
Replace or Repair the wiring
Check Fuse at Filter PCB.
Normally, If IGBT is damaged
and shorted, Fuse will blow and
power off.
YES
1. Replace the Fuse at Filter PCB.
If not change Fuse, Repaired Inverter
PCB will damage again.
2. Replace the Inverter PCB.