4 English
Installation requirements
Installation requirements
Product dimensions
B
A
D
C
E
F
Cabinet
30” (mm)
36” (mm)
A
Glass Depth
21
1
/
4
” (540)
21
1
/
4
” (540)
B
Glass Width
30” (762)
36” (914)
C
Case Depth
19
7
/
16
” (493.4)
19” (481.6)
D
Case Width
28
3
/
8
” (720)
33
3
/
4
” (856)
E
Condult Case Height
5
1
/
8
” (130.6)
5
1
/
8
” (130.6)
F
Case Height
3
5
/
8
” (92.4)
3
5
/
8
” (92.4)
Location requirements
IMPORTANT:
Observe all governing codes and ordinances.
•
Cabinet opening dimensions that are shown must be used.
Recessed installation area must provide complete enclosure around the
recessed portion of the cooktop.
•
Grounded electrical supply is required. See “Electrical Requirements” section.
NOTE
It is recommended to install the juction box on right side of the cabinet.
If installing the junction box near the left side, make sure the junction box does
not interfere with the cooktop (by concealing the junction box inside the wall).
IMPORTANT:
To avoid damage to your cabinets, check with your builder or
cabinet supplier to make sure that the materials used will not discolor, delaminate
or sustain other damage. This cooktop has been designed in accordance with
the requirements of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194 °F (90 °C).
Install_NZ30R5330_NZ36R5330_DG68-01157A-00_EN+MES+CFR.indb 4