Failure code
CAUSE
SOLUTION
E-24
Oven over heating
1.Disconnect power. Open the back cover. Disconnect sensor harness from control. Measure
sensor resistance : 1080
Ω at room temperature → If there are any problems, replace oven
sensor.
2. Check the broil, bake and convection heater. Check the resistance of the each heater.
3. Check whether DLB of Main PCB, Broil, Bake and Convection heater relay are
working
normally.
4. Check the wiring harness between the main PCB and the Assy Display.
5
. Check the resistance of oven sensor connector on the main PCB ( Normal : 2850
Ω)
6.It will display “E-24”after beeping 10 times Bzlong, if temperature is more than 600
℉
(316
℃
)
during oven is working excluding the case of self-cleaning.
7. Please make sure through the method of 4-1 , If those series of working for informing error
take long time or not functioned.
E-0E
Door locking error
*Control lockout(press cooking time and Delay
start pads at the same time for 3 seconds.)
When 1 minute elapsed, It will display “E-
0E” after buzzer is beeping 10 times long, if
locking is occurred continually, or door locking
is not working during self-cleaning or steam is
being operated.
E-21
Oven sensor opened
(over 2950Ω)
1. Disconnect power. Open the back cover.
Disconnect sensor harness from control
Measure sensor resistance
:1080Ω at the room temperature
→ If there are any problems, replace oven sensor.
2. If there is not any problem with oven sensor,
Please check whether there is a damaged
terminal or wire on harness.
3. Check resistance of oven sensor connector on
main PCB (Normal:2850Ω)
E-22
Oven sensor shorted.
(Under 930Ω)
E-83
Main PCB
communication error
1.
Check whether connector(CN201) of main PCB has been inserted.
2.
Check whether connector(CN202) of Assy Display has been inserted.
3.
If the connectors on the main PCB and Assy Display are in place, replace the main PCB.
E-84
Cooktop to Oven
Communication error
1.
Instantaneous electrical noise affects the micom signal when connecting the power
plug.
2.
Check the power cord to make sure it is tightly connected.
3.
Check the resistance of the IGBT on the inverter board. If the IGBT is shorted or open,
the inverter needs to be replaced.
4.
LVT of oven PCB is damaged or LVT connector is disconnected. Reconnect the LVT
connector or replace the oven main PCB.
-tE-
Assy Display
communication error
1. Check whether connector(TE201) of Assy Display has been inserted.
2.
If there is no problem with the connector on the Assy Display and touch glass, replace the
control box.
-dE-
Partition switch error
1.
Disconnect power. Open the back cover. Check the wire harness connection on the assy-
partition switch for proper connection.
2. Confirm whether resistance value of assy-partition switch is to be normal one or not.
-E-2E-
Partition switch error
1.
Disconnect power. Open the back cover. Disconnect Probe harness from control and
measure probe resistance :50k
Ω at room temperature → If there are any problem,
replace meat probe.
2. If there is no problem with the meat probe, check for damage to the terminals on the wire
harness.
3. Check the resistance of the meat probe connector on Main PCB (Normal : 10k
Ω ~ 11
k
Ω)