8 English
Ins
tallation
Installation
WARNING
Do not step on or twist the wires during installation, and keep them away from
heat-emitting parts of the oven.
Cabinet mount
If installing the oven in a built-in cabinet, the cabinet must have its plastic surfaces
and adhesive parts resistant up to 90 °C. Samsung is not responsible for damage to
furniture from the oven’s heat emission.
The oven must be properly ventilated. For ventilation, leave a gap of about 50 mm
between the lower shelf of the cabinet and the supporting wall. If you install the
oven under a cooktop, follow the cooktop’s installation instructions.
Required Dimensions for Installation
I
D
E
C
B
A
L
K
J
F
H
G
Oven (mm)
A
560
G
503
B
166
H
481
C
383
I
21
D
45
J
549
E
596
K
579
F
595
L
559
D
C
B
A
E
Built-in cabinet (mm)
A
Min. 550
B
Min. 560
C
Min. 50
D
Min. 590 - Max. 600
E
Min. 460 x Min. 50
NOTE
The built-in cabinet must have vents (
E
) to
ventilate heat and circulate the air.
D
C
B
A
Under-sink cabinet (mm)
A
Min. 550
B
Min. 560
C
Min. 600
D
Min. 460 x Min. 50
NOTE
The built-in cabinet must have vents (
D
) to
ventilate heat and circulate the air.
Installing with a hob
To install a hob on top of the oven, check
the installation guide of the hob for the
installation space requirement
( )
.
FULL MANUAL_NV7B4225ZAK_U2_DG68-01418A-00_EN.indd 8
FULL MANUAL_NV7B4225ZAK_U2_DG68-01418A-00_EN.indd 8
2022-02-21 오후 2:58:26