- 26 -
This document can not be used without Samsung’s authorization.
This document can not be used without Samsung’s authorization.
Imformation
Code
General Function
Solution
Excess of cooking com-
partment’s temperature
- This code occurs when a fire occurs inside cooking compart-ment
or the temperature caanot be controlled because of sensor’s failure.
- This code occurs the temperature of cooking compartment
reaches 350
℃
for 10sec
- This code occurs the temperature of cooking compartment
reaches 500
℃
in pyrolytic mode.
- This code occurs the temperature of cooking compartment
remains 250
℃
in Pyrolytic Cooling Stage for 50min.
- This code occurs the temperature of Assy Steamer reaches
130
℃
in steam mode.
Touch Button Short
This code occurs when a button is pressed and held for over
1 minute. It may occur when water soaks through the inside of the
control panel or dust particles are stuck to TOUCH PAD.
In this case, remove DISPLAY PCB, clean TOUCH PAD PCB or
replace it.
Overtime
Temp
Time
~ 100°C
16 hours
105°C ~ 240°C
8 hours
245°C ~
4 hours
This code occurs when the oven works during CUT-OFF TIME in
the same mode and at the same temperature without any
operation of an user. This error is to prevent a risk of fire and
hazards in case an user forgets to turn off the oven after use or
the oven automatically starts in an unusual way.
The oven can be used after off.
4-2-2 Safety Problem
Imformation
Code
General Function
Cause
Door Lock Problem
- This code occur when the door does not lock for 20sec after the
Pyrolytic mode reaches 270°C. It may occur when the door open
or door lock motor & door s/w does not operate.
Door Unlock Problem
- This code occur when the door does not unlock in 5th micom
signal after the Pyrolytic mode go down 170°C. It may occur
when the door lock motor & door s/w does not operate.
Communication
- Turn off and re check.
EEPROM can’t be
written or read
- Check the IC601.
Touch IC
Communication Problem
- Turn off and re check
Can not sensing divider
- Insert a divider in upper, lower and twin mode or remove a
divider in single mode.
- Please check divider sending S/W
4-2-3 Other Problem