Installing a 4-wire power cord
WARNING
WARNING
The neutral wire of the supply circuit must be connected
to the neutral terminal located in the lower center of the terminal block. The power leads
must be connected to the lower left and the lower right terminals of the terminal block.
The 4th grounding lead must be connected to the frame of the range with the ground
plate and the ground screw.
1.
Remove the 3 lower terminal screws from the terminal block. Remove the ground
screw and ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3.
Insert the ground screw into the power cord ground wire terminal ring, through the
ground plate, and into the frame of the range.
4.
Insert the 3 terminal screws (removed earlier) through each power cord terminal
ring and into the lower terminals of the terminal block. Be certain that the center
wire (white/neutral) is connected to the center lower position of the terminal block.
Tighten screws securely to the terminal black.
5.
Go to
Step 5
on page 15 to continue with the installation.
Ground strap
Ground plate
Ground
screw
Neutral
terminal
Ground
wire
(Green)
White
Black
Red
Black
White
Red
Live 2
Live 1
CAUTION
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
English - 12
Install_NE58H9970WS_AA_AC_DG68-00594B-00_EN+CFR.indb 12
6/7/2019 12:45:43 PM