21
EN
G
LIS
H
1)* The total option codes are 24 digits. You can set six digits at a time and it is distinguished by page number.
Press [>] button to go to the next page.
2)* If you enter Main menu #4, you must select the targeted indoor unit address and then select the sub menu.
3)* Setting is available when there is only 1 indoor unit connection and while the indoor unit operation is not operating.
4)* Power Master Reset is a setting needed to supply optimized power to wired remote controller when multiple indoor
units are connected to wired remote controller in a group.
1 2 3 4 5 6
Option Code
Page number
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
0
Page number
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
1
Page number
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
2
Page number
SEG19
SEG20
SEG21
SEG22
SEG23
SEG24
3
Page number
Regardless of Celsius and Fahrenheit setting, service mode setting is available only with Celsius.
Main
menu
Sub
menu
Function
Data
bit
Factory
setting
Description
Unit
7
1
Master setting/checking
(F3F4 line Indoor unit master)
Indoor unit Master setting/
checking
123456
-
address
-
2
ERV unit Master setting/
checking
123456
-
address
-
3
Mode master indoor unit
setting/checking
(F1F2 line Indoor unit master) 3)*
Mode master indoor unit
checking
123456
-
address
-
4
Mode master indoor unit setting
1
-
0-No use, 1-Use, 2-Release
-
0
1
Reset
Factory setting
1
0
0-No use, 1-Reset
-
2
Power Master Reset 4)*
1
0
0-No use, 1-Reset
-
3
Addressing Reset
1
0
0-No use, 1-Reset
-
NASA_Wired Remote Control_MWR-WE10N_EN_IM_03716A(1).indd 21